The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]

A hydrological study was conducted to determine their characteristics at Paka River, Terengganu. Seven sampling stations were identified in this study. Sampling was started from the estuary of Paka River, and ended about 14 km away from the estuary as each station was 2 km apart from each other. Sam...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Ekhwan, Toriman, Muhammad Barzani, Gasim, Haniff, Muhammad
Format: Article
Language:English
Published: Malaysian Society of Analytical Sciences 2015
Subjects:
Online Access:http://eprints.unisza.edu.my/6930/1/FH02-ESERI-15-04688.jpg
http://eprints.unisza.edu.my/6930/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-unisza-ir.6930
record_format eprints
spelling my-unisza-ir.69302022-09-13T05:50:03Z http://eprints.unisza.edu.my/6930/ The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia] Mohd Ekhwan, Toriman Muhammad Barzani, Gasim Haniff, Muhammad GE Environmental Sciences A hydrological study was conducted to determine their characteristics at Paka River, Terengganu. Seven sampling stations were identified in this study. Sampling was started from the estuary of Paka River, and ended about 14 km away from the estuary as each station was 2 km apart from each other. Sampling was carried out at two different water tides (low and high water tides) and two durational variations which represented by the wet and dry periods. Hydrological variables such as river velocity, river width and river depth were measured by using specific equipment. River width was measured by using a rangefinder (model Bushnell 20-0001), river depth was measured by using a depth meter (model Speedtech SM-5) and river velocity was measured by using a flow meter/current flow meter (model FP101). Station 1 that located at the downstream identified by highest readings for hydrological variables both water tides during the first and second samplings compared to stations 7 which located at the upstream. Higher readings of hydrological variables were also shown during dry season since low freshwater flow due to less rainfall intensity in the upstream area. Malaysian Society of Analytical Sciences 2015 Article PeerReviewed image en http://eprints.unisza.edu.my/6930/1/FH02-ESERI-15-04688.jpg Mohd Ekhwan, Toriman and Muhammad Barzani, Gasim and Haniff, Muhammad (2015) The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]. Malaysian Journal of Analytical Sciences, 19 (6). pp. 1382-1390. ISSN 13942506
institution Universiti Sultan Zainal Abidin
building UNISZA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sultan Zainal Abidin
content_source UNISZA Institutional Repository
url_provider https://eprints.unisza.edu.my/
language English
topic GE Environmental Sciences
spellingShingle GE Environmental Sciences
Mohd Ekhwan, Toriman
Muhammad Barzani, Gasim
Haniff, Muhammad
The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]
description A hydrological study was conducted to determine their characteristics at Paka River, Terengganu. Seven sampling stations were identified in this study. Sampling was started from the estuary of Paka River, and ended about 14 km away from the estuary as each station was 2 km apart from each other. Sampling was carried out at two different water tides (low and high water tides) and two durational variations which represented by the wet and dry periods. Hydrological variables such as river velocity, river width and river depth were measured by using specific equipment. River width was measured by using a rangefinder (model Bushnell 20-0001), river depth was measured by using a depth meter (model Speedtech SM-5) and river velocity was measured by using a flow meter/current flow meter (model FP101). Station 1 that located at the downstream identified by highest readings for hydrological variables both water tides during the first and second samplings compared to stations 7 which located at the upstream. Higher readings of hydrological variables were also shown during dry season since low freshwater flow due to less rainfall intensity in the upstream area.
format Article
author Mohd Ekhwan, Toriman
Muhammad Barzani, Gasim
Haniff, Muhammad
author_facet Mohd Ekhwan, Toriman
Muhammad Barzani, Gasim
Haniff, Muhammad
author_sort Mohd Ekhwan, Toriman
title The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]
title_short The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]
title_full The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]
title_fullStr The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]
title_full_unstemmed The influence of tidal activities on hydrologic variables of Paka river, Terengganu, Malaysia [Pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai Paka, Terengganu, Malaysia]
title_sort influence of tidal activities on hydrologic variables of paka river, terengganu, malaysia [pengaruh aktiviti pasang surut bagi variabel hidrologi di sungai paka, terengganu, malaysia]
publisher Malaysian Society of Analytical Sciences
publishDate 2015
url http://eprints.unisza.edu.my/6930/1/FH02-ESERI-15-04688.jpg
http://eprints.unisza.edu.my/6930/
_version_ 1744358574943895552
score 13.154949