Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization.

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzyme deficiency worldwide including Malaysia. Screening of cord blood for partial G6PD deficiency is important as they are also prone to develop acute haemolysis. In this study, we determined the prevalence of partial G6PD defi...

Full description

Saved in:
Bibliographic Details
Main Authors: Azma RZ,, Siti Zubaidah M,, Azlin I,, Hafiza A,, Nurasyikin Y,, Nor Hidayati S,, Noor Farisah AR,, Noor Hamidah H,, Ainoon O,
Format: Article
Language:English
Published: Penerbit UKM 2014
Online Access:http://journalarticle.ukm.my/8102/1/02-MS181-_Proof_%2811-21%29.pdf
http://journalarticle.ukm.my/8102/
http://www.ppukm.ukm.my/ukmmcjournal/index.php
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.8102
record_format eprints
spelling my-ukm.journal.81022016-12-14T06:46:13Z http://journalarticle.ukm.my/8102/ Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization. Azma RZ, Siti Zubaidah M, Azlin I, Hafiza A, Nurasyikin Y, Nor Hidayati S, Noor Farisah AR, Noor Hamidah H, Ainoon O, Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzyme deficiency worldwide including Malaysia. Screening of cord blood for partial G6PD deficiency is important as they are also prone to develop acute haemolysis. In this study, we determined the prevalence of partial G6PD deficient in paediatric population aged 1 month-12 years and normal term female neonates using OSMMR-D kit with haemoglobin (Hb) normalization and compare it with florescence spot test (FST). A total of 236 children, aged between between 1 month-12 years and 614 normal term female neonates were recruited for this study. Determination of normal means for G6PD activity and; cut-off points for partial and severe deficiency were determined according to WHO Working Group (1989). Determination of prevalence for partial deficiency for both groups (female patient) was done using this enzyme assay kit and findings were compared with FST. In this study, 15.7% (18/115) female children were classified as partial G6PD deficient by quantitative enzyme method (G6PD activity: 4.23-5.26U/gHb). However, FST only detected 0.9% (1/115) with minimal G6PD activity. The prevalence of partial G6PD deficiency in female neonate group was 3.42% (21/614) by enzyme assay versus 0.49% (3/614) by FST. This study concluded that our routine screening method using FST was unable to diagnose female heterozygotes. We recommend using this quantitative enzyme assay method by OSMMR-D kit since it was more sensitive in detecting G6PD deficiency in female neonates compared to FST. Penerbit UKM 2014-01-01 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/8102/1/02-MS181-_Proof_%2811-21%29.pdf Azma RZ, and Siti Zubaidah M, and Azlin I, and Hafiza A, and Nurasyikin Y, and Nor Hidayati S, and Noor Farisah AR, and Noor Hamidah H, and Ainoon O, (2014) Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization. Medicine & Health, 9 (1). pp. 11-21. ISSN 1823-2140 http://www.ppukm.ukm.my/ukmmcjournal/index.php
institution Universiti Kebangsaan Malaysia
building Perpustakaan Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzyme deficiency worldwide including Malaysia. Screening of cord blood for partial G6PD deficiency is important as they are also prone to develop acute haemolysis. In this study, we determined the prevalence of partial G6PD deficient in paediatric population aged 1 month-12 years and normal term female neonates using OSMMR-D kit with haemoglobin (Hb) normalization and compare it with florescence spot test (FST). A total of 236 children, aged between between 1 month-12 years and 614 normal term female neonates were recruited for this study. Determination of normal means for G6PD activity and; cut-off points for partial and severe deficiency were determined according to WHO Working Group (1989). Determination of prevalence for partial deficiency for both groups (female patient) was done using this enzyme assay kit and findings were compared with FST. In this study, 15.7% (18/115) female children were classified as partial G6PD deficient by quantitative enzyme method (G6PD activity: 4.23-5.26U/gHb). However, FST only detected 0.9% (1/115) with minimal G6PD activity. The prevalence of partial G6PD deficiency in female neonate group was 3.42% (21/614) by enzyme assay versus 0.49% (3/614) by FST. This study concluded that our routine screening method using FST was unable to diagnose female heterozygotes. We recommend using this quantitative enzyme assay method by OSMMR-D kit since it was more sensitive in detecting G6PD deficiency in female neonates compared to FST.
format Article
author Azma RZ,
Siti Zubaidah M,
Azlin I,
Hafiza A,
Nurasyikin Y,
Nor Hidayati S,
Noor Farisah AR,
Noor Hamidah H,
Ainoon O,
spellingShingle Azma RZ,
Siti Zubaidah M,
Azlin I,
Hafiza A,
Nurasyikin Y,
Nor Hidayati S,
Noor Farisah AR,
Noor Hamidah H,
Ainoon O,
Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization.
author_facet Azma RZ,
Siti Zubaidah M,
Azlin I,
Hafiza A,
Nurasyikin Y,
Nor Hidayati S,
Noor Farisah AR,
Noor Hamidah H,
Ainoon O,
author_sort Azma RZ,
title Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization.
title_short Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization.
title_full Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization.
title_fullStr Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization.
title_full_unstemmed Detection of partial G6PD deficiency using OSMMR2000-D kit with Hb normalization.
title_sort detection of partial g6pd deficiency using osmmr2000-d kit with hb normalization.
publisher Penerbit UKM
publishDate 2014
url http://journalarticle.ukm.my/8102/1/02-MS181-_Proof_%2811-21%29.pdf
http://journalarticle.ukm.my/8102/
http://www.ppukm.ukm.my/ukmmcjournal/index.php
_version_ 1643737363710476288
score 13.18916