Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams

The values of beam quality correction factor kQ that were experimentally determined from year 2002 to 2008 were analysed. As kQ is the function of ionization chamber and beam quality, the analysis were based on three cases namely (a) kQ(NE2571, 6 MV x-rays) that were determined from 17 measurement...

Full description

Saved in:
Bibliographic Details
Main Authors: Samat S.B,, Too S.X,, Kadni T,, Dolah M.T,
Format: Article
Language:English
Published: Universiti Kebangsaan Malaysia 2009
Online Access:http://journalarticle.ukm.my/68/1/
http://journalarticle.ukm.my/68/
http://www.ukm.my/~jsm/kandungan.html
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.68
record_format eprints
spelling my-ukm.journal.682016-12-14T06:26:19Z http://journalarticle.ukm.my/68/ Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams Samat S.B, Too S.X, Kadni T, Dolah M.T, The values of beam quality correction factor kQ that were experimentally determined from year 2002 to 2008 were analysed. As kQ is the function of ionization chamber and beam quality, the analysis were based on three cases namely (a) kQ(NE2571, 6 MV x-rays) that were determined from 17 measurements in the duration of 69 months at 6 radiotherapy centres, (b) kQ(NE2571, 10 MV x-rays) from 7 measurements in the duration of 12 months at one radiotherapy centre, and (c) kQ(NE2581, 6 MV x-rays) from 5 measurements in the duration of 5 months also at one radiotherapy centre. The purpose is to examine, in each case, the variation kQ for all the measurements. In other words, to see the variation of kQ with time. Results obtained are 0.993(NE2571, 6 MV), 0.986(NE2571, 10 MV) and 0.986(NE2581, 6 MV). This shows that in each case, despite the difference in the experimental data in getting kQ for all measurement, kQ remains constant with time. Reasons for this are explained. Universiti Kebangsaan Malaysia 2009-04 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/68/1/ Samat S.B, and Too S.X, and Kadni T, and Dolah M.T, (2009) Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams. Sains Malaysiana, 38 (2). pp. 203-207. ISSN 0126-6039 http://www.ukm.my/~jsm/kandungan.html
institution Universiti Kebangsaan Malaysia
building Perpustakaan Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description The values of beam quality correction factor kQ that were experimentally determined from year 2002 to 2008 were analysed. As kQ is the function of ionization chamber and beam quality, the analysis were based on three cases namely (a) kQ(NE2571, 6 MV x-rays) that were determined from 17 measurements in the duration of 69 months at 6 radiotherapy centres, (b) kQ(NE2571, 10 MV x-rays) from 7 measurements in the duration of 12 months at one radiotherapy centre, and (c) kQ(NE2581, 6 MV x-rays) from 5 measurements in the duration of 5 months also at one radiotherapy centre. The purpose is to examine, in each case, the variation kQ for all the measurements. In other words, to see the variation of kQ with time. Results obtained are 0.993(NE2571, 6 MV), 0.986(NE2571, 10 MV) and 0.986(NE2581, 6 MV). This shows that in each case, despite the difference in the experimental data in getting kQ for all measurement, kQ remains constant with time. Reasons for this are explained.
format Article
author Samat S.B,
Too S.X,
Kadni T,
Dolah M.T,
spellingShingle Samat S.B,
Too S.X,
Kadni T,
Dolah M.T,
Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams
author_facet Samat S.B,
Too S.X,
Kadni T,
Dolah M.T,
author_sort Samat S.B,
title Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams
title_short Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams
title_full Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams
title_fullStr Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams
title_full_unstemmed Variation of beam quality correction factor with time: Cases for NE2571 and NE2581 chambers in the 6 and 10 MV x-rays Beams
title_sort variation of beam quality correction factor with time: cases for ne2571 and ne2581 chambers in the 6 and 10 mv x-rays beams
publisher Universiti Kebangsaan Malaysia
publishDate 2009
url http://journalarticle.ukm.my/68/1/
http://journalarticle.ukm.my/68/
http://www.ukm.my/~jsm/kandungan.html
_version_ 1643734605671432192
score 13.160551