Fitted curve paramaters for the efficiency of a coaxial HPGe detector

Using Ngraph software, the parameters of various functions were deter­mined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by...

Full description

Saved in:
Bibliographic Details
Main Author: Supian Samat,
Format: Article
Published: Universiti Kebangsaan Malaysia 1996
Online Access:http://journalarticle.ukm.my/3690/
http://www.ukm.my/jsm/english_journals/vol25num2_1996/vol25num2_96page27-34.html
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.3690
record_format eprints
spelling my-ukm.journal.36902012-04-30T06:50:34Z http://journalarticle.ukm.my/3690/ Fitted curve paramaters for the efficiency of a coaxial HPGe detector Supian Samat, Using Ngraph software, the parameters of various functions were deter­mined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by the calculated goodness-of-fit parameter χ2cal It is shown that the function, where n = 3, gives satisfactory results. Universiti Kebangsaan Malaysia 1996-06 Article PeerReviewed Supian Samat, (1996) Fitted curve paramaters for the efficiency of a coaxial HPGe detector. Sains Malaysiana, 25 (2). pp. 27-34. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol25num2_1996/vol25num2_96page27-34.html
institution Universiti Kebangsaan Malaysia
building Perpustakaan Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
description Using Ngraph software, the parameters of various functions were deter­mined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by the calculated goodness-of-fit parameter χ2cal It is shown that the function, where n = 3, gives satisfactory results.
format Article
author Supian Samat,
spellingShingle Supian Samat,
Fitted curve paramaters for the efficiency of a coaxial HPGe detector
author_facet Supian Samat,
author_sort Supian Samat,
title Fitted curve paramaters for the efficiency of a coaxial HPGe detector
title_short Fitted curve paramaters for the efficiency of a coaxial HPGe detector
title_full Fitted curve paramaters for the efficiency of a coaxial HPGe detector
title_fullStr Fitted curve paramaters for the efficiency of a coaxial HPGe detector
title_full_unstemmed Fitted curve paramaters for the efficiency of a coaxial HPGe detector
title_sort fitted curve paramaters for the efficiency of a coaxial hpge detector
publisher Universiti Kebangsaan Malaysia
publishDate 1996
url http://journalarticle.ukm.my/3690/
http://www.ukm.my/jsm/english_journals/vol25num2_1996/vol25num2_96page27-34.html
_version_ 1643735812118937600
score 13.211869