Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City)

Fresh air circulation in a room had an impact on indoor air quality. In today’s pandemic, good fresh air circulation is one of the main strategies to prevent viruses from spreading through air molecules. A good ventilation opening design influences indoor air exchange. This research conducts a test...

Full description

Saved in:
Bibliographic Details
Main Authors: Tri Woro Setiati,, Sandra Eka Febrina,, Fajar Sadik Islamia,
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2023
Online Access:http://journalarticle.ukm.my/23471/1/26.pdf
http://journalarticle.ukm.my/23471/
https://www.ukm.my/jkukm/si-6-1-2023/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.23471
record_format eprints
spelling my-ukm.journal.234712024-05-10T01:50:58Z http://journalarticle.ukm.my/23471/ Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City) Tri Woro Setiati, Sandra Eka Febrina, Fajar Sadik Islamia, Fresh air circulation in a room had an impact on indoor air quality. In today’s pandemic, good fresh air circulation is one of the main strategies to prevent viruses from spreading through air molecules. A good ventilation opening design influences indoor air exchange. This research conducts a test on lower ventilation opening design that can maximize natural ventilation performance in a classroom. This test aimed at a recommendation for schools in the tropical humid region so they can hold offline learning with low virus spreads. Natural ventilation optimization should be a solution because not everyone can afford mechanical air filters or virus killers. This research used an experimental method. Computer simulation test variables were classroom openings consisting of existing openings, new outlets/openings, and lower ventilation opening. Parameters of observation are wind velocity, air circulation pattern, and air change per hour. This evaluation compares the experiment result to Air Change per Hour (ACH) threshold limit provision required in Indonesia. The result of the experiment shows outlet/opening addition provides a better impact on ACH escalation than with only existing classroom opening. And when the existing opening is closed, lower ventilation opening had good performance in achieving the ACH threshold limit provision requirements which were 9,8 ACH. Penerbit Universiti Kebangsaan Malaysia 2023 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/23471/1/26.pdf Tri Woro Setiati, and Sandra Eka Febrina, and Fajar Sadik Islamia, (2023) Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City). Jurnal Kejuruteraan, SI-6 (1). pp. 299-309. ISSN 0128-0198 https://www.ukm.my/jkukm/si-6-1-2023/
institution Universiti Kebangsaan Malaysia
building Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description Fresh air circulation in a room had an impact on indoor air quality. In today’s pandemic, good fresh air circulation is one of the main strategies to prevent viruses from spreading through air molecules. A good ventilation opening design influences indoor air exchange. This research conducts a test on lower ventilation opening design that can maximize natural ventilation performance in a classroom. This test aimed at a recommendation for schools in the tropical humid region so they can hold offline learning with low virus spreads. Natural ventilation optimization should be a solution because not everyone can afford mechanical air filters or virus killers. This research used an experimental method. Computer simulation test variables were classroom openings consisting of existing openings, new outlets/openings, and lower ventilation opening. Parameters of observation are wind velocity, air circulation pattern, and air change per hour. This evaluation compares the experiment result to Air Change per Hour (ACH) threshold limit provision required in Indonesia. The result of the experiment shows outlet/opening addition provides a better impact on ACH escalation than with only existing classroom opening. And when the existing opening is closed, lower ventilation opening had good performance in achieving the ACH threshold limit provision requirements which were 9,8 ACH.
format Article
author Tri Woro Setiati,
Sandra Eka Febrina,
Fajar Sadik Islamia,
spellingShingle Tri Woro Setiati,
Sandra Eka Febrina,
Fajar Sadik Islamia,
Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City)
author_facet Tri Woro Setiati,
Sandra Eka Febrina,
Fajar Sadik Islamia,
author_sort Tri Woro Setiati,
title Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City)
title_short Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City)
title_full Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City)
title_fullStr Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City)
title_full_unstemmed Performance of Lower Ventilation Opening to Improve Air Change per Hour in Classroom at Tropical Humid Region (Case Study: Palembang City)
title_sort performance of lower ventilation opening to improve air change per hour in classroom at tropical humid region (case study: palembang city)
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2023
url http://journalarticle.ukm.my/23471/1/26.pdf
http://journalarticle.ukm.my/23471/
https://www.ukm.my/jkukm/si-6-1-2023/
_version_ 1800088750652391424
score 13.211869