Simulation of PEMFC stack for portable power generator application

Generally, it is possible to reduce the size, cost, and parasitic loss of polymer electrolyte membrane fuel cell (PEMFC) system with an air-cooled system, open cathode and self-humidifying stack for portable fuel cell application. In order to ensure the that PEMFC stack applicable for portable f...

Full description

Saved in:
Bibliographic Details
Main Authors: Siti Najibah Abd Rahman,, Mohd Shahbudin Masdar,, Masli Irwan Rosli,, Edy Herianto Majlan,, Syahril Anuar Md Rejab,, Chew, Chien Lye
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2018
Online Access:http://journalarticle.ukm.my/20524/1/1.pdf
http://journalarticle.ukm.my/20524/
https://www.ukm.my/jkukm/si-1-1-2018/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.20524
record_format eprints
spelling my-ukm.journal.205242022-11-16T08:47:49Z http://journalarticle.ukm.my/20524/ Simulation of PEMFC stack for portable power generator application Siti Najibah Abd Rahman, Mohd Shahbudin Masdar, Masli Irwan Rosli, Edy Herianto Majlan, Syahril Anuar Md Rejab, Chew, Chien Lye Generally, it is possible to reduce the size, cost, and parasitic loss of polymer electrolyte membrane fuel cell (PEMFC) system with an air-cooled system, open cathode and self-humidifying stack for portable fuel cell application. In order to ensure the that PEMFC stack applicable for portable fuel cell application, a mathematical model is useful tool for saving design cost, giving a better system design and operation. Therefore, this study is focused on developing a simplified zero-dimensional mathematical model for self-humidifying and open cathode 200W PEMFC stack for portable fuel cell generator application. The mathematical equations are modelled by using Matlab-Simulink tools in order to simulate the operation of the developed mode. This simulation is then compared to a commercially 200W Horizon PEMFC stack (H-200) for data validation purposes. The air inlet flow rate is chosen to test the sensitivity of the fuel cell stack model. The air inlet stoichiometry of 2, 5, 20, and 50 was varied to generate a different air inlet flow rate. Based on the simulation, air inlet stoichiometry above 15 is sufficient to produce a high output stack voltage. However, in a real operation of the H-200 fuel cell stack system needs air inlet stoichiometry at about 20 because a fan is used to supply air and also the cooling system. High anode and cathode relative humidity result in a high output stack voltage. However, it is better to increase the anode relative humidity than cathode relative humidity to get high output stack voltage. Penerbit Universiti Kebangsaan Malaysia 2018 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/20524/1/1.pdf Siti Najibah Abd Rahman, and Mohd Shahbudin Masdar, and Masli Irwan Rosli, and Edy Herianto Majlan, and Syahril Anuar Md Rejab, and Chew, Chien Lye (2018) Simulation of PEMFC stack for portable power generator application. Jurnal Kejuruteraan, 1 (1(SI)). pp. 1-10. ISSN 0128-0198 https://www.ukm.my/jkukm/si-1-1-2018/
institution Universiti Kebangsaan Malaysia
building Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description Generally, it is possible to reduce the size, cost, and parasitic loss of polymer electrolyte membrane fuel cell (PEMFC) system with an air-cooled system, open cathode and self-humidifying stack for portable fuel cell application. In order to ensure the that PEMFC stack applicable for portable fuel cell application, a mathematical model is useful tool for saving design cost, giving a better system design and operation. Therefore, this study is focused on developing a simplified zero-dimensional mathematical model for self-humidifying and open cathode 200W PEMFC stack for portable fuel cell generator application. The mathematical equations are modelled by using Matlab-Simulink tools in order to simulate the operation of the developed mode. This simulation is then compared to a commercially 200W Horizon PEMFC stack (H-200) for data validation purposes. The air inlet flow rate is chosen to test the sensitivity of the fuel cell stack model. The air inlet stoichiometry of 2, 5, 20, and 50 was varied to generate a different air inlet flow rate. Based on the simulation, air inlet stoichiometry above 15 is sufficient to produce a high output stack voltage. However, in a real operation of the H-200 fuel cell stack system needs air inlet stoichiometry at about 20 because a fan is used to supply air and also the cooling system. High anode and cathode relative humidity result in a high output stack voltage. However, it is better to increase the anode relative humidity than cathode relative humidity to get high output stack voltage.
format Article
author Siti Najibah Abd Rahman,
Mohd Shahbudin Masdar,
Masli Irwan Rosli,
Edy Herianto Majlan,
Syahril Anuar Md Rejab,
Chew, Chien Lye
spellingShingle Siti Najibah Abd Rahman,
Mohd Shahbudin Masdar,
Masli Irwan Rosli,
Edy Herianto Majlan,
Syahril Anuar Md Rejab,
Chew, Chien Lye
Simulation of PEMFC stack for portable power generator application
author_facet Siti Najibah Abd Rahman,
Mohd Shahbudin Masdar,
Masli Irwan Rosli,
Edy Herianto Majlan,
Syahril Anuar Md Rejab,
Chew, Chien Lye
author_sort Siti Najibah Abd Rahman,
title Simulation of PEMFC stack for portable power generator application
title_short Simulation of PEMFC stack for portable power generator application
title_full Simulation of PEMFC stack for portable power generator application
title_fullStr Simulation of PEMFC stack for portable power generator application
title_full_unstemmed Simulation of PEMFC stack for portable power generator application
title_sort simulation of pemfc stack for portable power generator application
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2018
url http://journalarticle.ukm.my/20524/1/1.pdf
http://journalarticle.ukm.my/20524/
https://www.ukm.my/jkukm/si-1-1-2018/
_version_ 1751537473866956800
score 13.160551