The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study

Selective laser melting (SLM) is a new technique in fabricating cobalt-chromium denture framework. However, the surface properties of cobalt-chromium denture framework fabricated using the aforementioned technique have not been widely investigated. The aim of this paper was to investigate the surfac...

Full description

Saved in:
Bibliographic Details
Main Authors: Aini Hayati Abdul Rahim,, Zubaidah Zanul Abidin,, Norsiah Yunus,
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2021
Online Access:http://journalarticle.ukm.my/18176/1/18.pdf
http://journalarticle.ukm.my/18176/
https://www.ukm.my/jsm/malay_journals/jilid50bil10_2021/KandunganJilid50Bil10_2021.html
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.18176
record_format eprints
spelling my-ukm.journal.181762022-03-07T03:27:03Z http://journalarticle.ukm.my/18176/ The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study Aini Hayati Abdul Rahim, Zubaidah Zanul Abidin, Norsiah Yunus, Selective laser melting (SLM) is a new technique in fabricating cobalt-chromium denture framework. However, the surface properties of cobalt-chromium denture framework fabricated using the aforementioned technique have not been widely investigated. The aim of this paper was to investigate the surface roughness of cobalt-chromium alloy in removable partial denture fabricated with SLM technique. Cobalt-chromium denture frameworks were fabricated with two techniques (n = 10); the conventional lost-wax casting (conventional group) and SLM techniques (SLM group). Specimens from the conventional group were subjected to the standard cobalt-chromium denture polishing protocols. No treatment was employed for specimens from the SLM group. All specimens were subjected to surface roughness measurement on polished and fitting surfaces using non-contact optical three-dimensional metrology and surface roughness analysis machine (Infinite Focus Real 3D Alicona). Statistical analysis showed no significant difference in surface roughness between the specimens from conventional and SLM groups (p > 0.05). There was no statistically significant difference in surface roughness between the polished and fitting surfaces of SLM specimens (p > 0.05). Surface roughness quality of the cobalt-chromium denture framework fabricated with the SLM technique is comparable to that fabricated with the conventional lost-wax casting technique. The surface roughness of SLM fabricated cobalt-chromium denture frameworks carries the same surface roughness quality between the polished and fitting surfaces. Penerbit Universiti Kebangsaan Malaysia 2021-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/18176/1/18.pdf Aini Hayati Abdul Rahim, and Zubaidah Zanul Abidin, and Norsiah Yunus, (2021) The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study. Sains Malaysiana, 50 (10). pp. 3059-3065. ISSN 0126-6039 https://www.ukm.my/jsm/malay_journals/jilid50bil10_2021/KandunganJilid50Bil10_2021.html
institution Universiti Kebangsaan Malaysia
building Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description Selective laser melting (SLM) is a new technique in fabricating cobalt-chromium denture framework. However, the surface properties of cobalt-chromium denture framework fabricated using the aforementioned technique have not been widely investigated. The aim of this paper was to investigate the surface roughness of cobalt-chromium alloy in removable partial denture fabricated with SLM technique. Cobalt-chromium denture frameworks were fabricated with two techniques (n = 10); the conventional lost-wax casting (conventional group) and SLM techniques (SLM group). Specimens from the conventional group were subjected to the standard cobalt-chromium denture polishing protocols. No treatment was employed for specimens from the SLM group. All specimens were subjected to surface roughness measurement on polished and fitting surfaces using non-contact optical three-dimensional metrology and surface roughness analysis machine (Infinite Focus Real 3D Alicona). Statistical analysis showed no significant difference in surface roughness between the specimens from conventional and SLM groups (p > 0.05). There was no statistically significant difference in surface roughness between the polished and fitting surfaces of SLM specimens (p > 0.05). Surface roughness quality of the cobalt-chromium denture framework fabricated with the SLM technique is comparable to that fabricated with the conventional lost-wax casting technique. The surface roughness of SLM fabricated cobalt-chromium denture frameworks carries the same surface roughness quality between the polished and fitting surfaces.
format Article
author Aini Hayati Abdul Rahim,
Zubaidah Zanul Abidin,
Norsiah Yunus,
spellingShingle Aini Hayati Abdul Rahim,
Zubaidah Zanul Abidin,
Norsiah Yunus,
The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study
author_facet Aini Hayati Abdul Rahim,
Zubaidah Zanul Abidin,
Norsiah Yunus,
author_sort Aini Hayati Abdul Rahim,
title The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study
title_short The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study
title_full The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study
title_fullStr The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study
title_full_unstemmed The digitalisation in cobalt-chromium framework fabrication. Surface roughness analysis : a pilot study
title_sort digitalisation in cobalt-chromium framework fabrication. surface roughness analysis : a pilot study
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2021
url http://journalarticle.ukm.my/18176/1/18.pdf
http://journalarticle.ukm.my/18176/
https://www.ukm.my/jsm/malay_journals/jilid50bil10_2021/KandunganJilid50Bil10_2021.html
_version_ 1726792373190524928
score 13.160551