Computer aided simulation POME biogas purification system
About three (3) tonnes of palm oil mill effluent (POME) is generated when one (1) tonne of crude palm oil (CPO) is produced. Microbial digestion treatment is commonly used in Malaysian palm oil mills due to the low capital expenditure (CAPEX) and operational expenditure (OPEX). However, anaerobic...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Universiti Kebangsaan Malaysia
2021
|
Online Access: | http://journalarticle.ukm.my/17812/1/15.pdf http://journalarticle.ukm.my/17812/ https://www.ukm.my/jkukm/volume-332-2021/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | About three (3) tonnes of palm oil mill effluent (POME) is generated when one (1) tonne of crude palm oil (CPO) is
produced. Microbial digestion treatment is commonly used in Malaysian palm oil mills due to the low capital expenditure
(CAPEX) and operational expenditure (OPEX). However, anaerobic digestion of POME produces methane gas which is 21
times more harmful than carbon dioxide. 1m3 of POME could generate 27m3of biogas at standard temperature and pressure
with approximate caloric value of 20 MJm-3 under optimum conditions Thus, methane capturing biogas plant to address
sustainability issue is included as part of effluent treatment plant. Many mills start to utilise the biogas energy to replace
palm kernel shell which could be sold as renewable solid fuel. Although untreated biogas may be good enough for boiler
fuel, internal combustion engines need a fairly homogeneous fuel with methane (CH4) content up to 80 % and hydrogen
sulphite (H2S) content less than 200 ppm in order to ensure the optimum engine performance. Water scrubber system
is widely used in gas purification. Computer aided biogas purification system simulation involving water scrubber and
flashing drum is presented in the effort to produce IC engine fuel. ChemCAD simulation result shows that POME biogas
purification process is feasible at 10 bar pressure and 25°C ambient temperature. |
---|