Absorption of electromagnetic radiation on human lower back region

In this paper a simulation study is conducted on lower back region of human phantom to observe the absorption of electromagnetic (EM) radiation. To investigate the effectiveness, EM radiation with different frequencies (1-100 GHz) is administrated step by step in different tissue thickness (up t...

Full description

Saved in:
Bibliographic Details
Main Authors: Shakoor, M A, Moyeenuzzaman, M, Azim, R, Chakraborty, S R, M T Islam,, Samsuzzaman, M
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2021
Online Access:http://journalarticle.ukm.my/16484/1/14.pdf
http://journalarticle.ukm.my/16484/
https://www.ukm.my/jkukm/volume-331-2021/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.16484
record_format eprints
spelling my-ukm.journal.164842021-04-26T07:05:25Z http://journalarticle.ukm.my/16484/ Absorption of electromagnetic radiation on human lower back region Shakoor, M A Moyeenuzzaman, M Azim, R Chakraborty, S R M T Islam, Samsuzzaman, M In this paper a simulation study is conducted on lower back region of human phantom to observe the absorption of electromagnetic (EM) radiation. To investigate the effectiveness, EM radiation with different frequencies (1-100 GHz) is administrated step by step in different tissue thickness (up to 25 mm) of lower back region of human phantom and using EM simulator HFSS, return loss (RL) is recorded at every stage. From the results, it is found that when radiation with frequency 0.899 GHz to 1. 089 GHz (~1 GHz) is applied return loss is varies from 0.413 dB to 1.022 dB in different thicknesses. This indicates that only 1.1 % of the incident power is absorbed maximally. When radiation of 9.899 GHz to 10.099 GHz (~10 GHz) frequency is applied, the return loss value obtained is 6.731 dB to 6.280 dB for different tissue thicknesses. This indicates that only 10.1 % power is absorbed maximally. Finally, when radiation with frequency 99.899 GHz to 100.1 GHz (~ 0.1 THz) is applied, the return loss value is found ranging from 26.902 dB to 26.429 dB in different thicknesses which indicates that almost 99.9% of the incident radiation is absorbed by the human tissue i.e. almost 100% of the incident radiation is absorbed in human lower back region in THz range. From therapeutic point of view, almost the entire incident radiation is attenuated to the lower back region with THz radiation which is clinically very useful in treating chronic low back pain. Penerbit Universiti Kebangsaan Malaysia 2021 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/16484/1/14.pdf Shakoor, M A and Moyeenuzzaman, M and Azim, R and Chakraborty, S R and M T Islam, and Samsuzzaman, M (2021) Absorption of electromagnetic radiation on human lower back region. Jurnal Kejuruteraan, 33 (1). pp. 141-145. ISSN 0128-0198 https://www.ukm.my/jkukm/volume-331-2021/
institution Universiti Kebangsaan Malaysia
building Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description In this paper a simulation study is conducted on lower back region of human phantom to observe the absorption of electromagnetic (EM) radiation. To investigate the effectiveness, EM radiation with different frequencies (1-100 GHz) is administrated step by step in different tissue thickness (up to 25 mm) of lower back region of human phantom and using EM simulator HFSS, return loss (RL) is recorded at every stage. From the results, it is found that when radiation with frequency 0.899 GHz to 1. 089 GHz (~1 GHz) is applied return loss is varies from 0.413 dB to 1.022 dB in different thicknesses. This indicates that only 1.1 % of the incident power is absorbed maximally. When radiation of 9.899 GHz to 10.099 GHz (~10 GHz) frequency is applied, the return loss value obtained is 6.731 dB to 6.280 dB for different tissue thicknesses. This indicates that only 10.1 % power is absorbed maximally. Finally, when radiation with frequency 99.899 GHz to 100.1 GHz (~ 0.1 THz) is applied, the return loss value is found ranging from 26.902 dB to 26.429 dB in different thicknesses which indicates that almost 99.9% of the incident radiation is absorbed by the human tissue i.e. almost 100% of the incident radiation is absorbed in human lower back region in THz range. From therapeutic point of view, almost the entire incident radiation is attenuated to the lower back region with THz radiation which is clinically very useful in treating chronic low back pain.
format Article
author Shakoor, M A
Moyeenuzzaman, M
Azim, R
Chakraborty, S R
M T Islam,
Samsuzzaman, M
spellingShingle Shakoor, M A
Moyeenuzzaman, M
Azim, R
Chakraborty, S R
M T Islam,
Samsuzzaman, M
Absorption of electromagnetic radiation on human lower back region
author_facet Shakoor, M A
Moyeenuzzaman, M
Azim, R
Chakraborty, S R
M T Islam,
Samsuzzaman, M
author_sort Shakoor, M A
title Absorption of electromagnetic radiation on human lower back region
title_short Absorption of electromagnetic radiation on human lower back region
title_full Absorption of electromagnetic radiation on human lower back region
title_fullStr Absorption of electromagnetic radiation on human lower back region
title_full_unstemmed Absorption of electromagnetic radiation on human lower back region
title_sort absorption of electromagnetic radiation on human lower back region
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2021
url http://journalarticle.ukm.my/16484/1/14.pdf
http://journalarticle.ukm.my/16484/
https://www.ukm.my/jkukm/volume-331-2021/
_version_ 1698697936597155840
score 13.188404