Heavy metals leaching behaviour assessment of palm oil clinker
Technical benefit of incorporation of Palm Oil Clinker (POC) in cement-based applications has been proven in recent studies. The aim of this work was to assess the heavy metal leaching behavior to ensure environmental safety of using POC in cement-based applications. The chemical composition, morpho...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Universiti Kebangsaan Malaysia
2018
|
Online Access: | http://journalarticle.ukm.my/12034/1/12%20MOHAMMAD%20RAZAUL%20KARIM.pdf http://journalarticle.ukm.my/12034/ http://www.ukm.my/jsm/malay_journals/jilid47bil3_2018/KandunganJilid47Bil3_2018.html |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-ukm.journal.12034 |
---|---|
record_format |
eprints |
spelling |
my-ukm.journal.120342018-09-09T23:22:24Z http://journalarticle.ukm.my/12034/ Heavy metals leaching behaviour assessment of palm oil clinker Mohammad Razaul Karim, Sumiani Yusoff, Hashim Abdul Razak, Faisal I. Chowdhury, Hossain Zabed, Technical benefit of incorporation of Palm Oil Clinker (POC) in cement-based applications has been proven in recent studies. The aim of this work was to assess the heavy metal leaching behavior to ensure environmental safety of using POC in cement-based applications. The chemical composition, morphology, total organic carbon (TOC) and mineralogy were determined using XRF, FESEM, TOC analyzers and XRD to select appropriate chemical reagents for complete digestion. HNO3, HF and HClO4 were used for digestion of POC to measure heavy metal content using ICP-MS. The chemical reagents CH3COOH, NH2OH-HCl, H2O2+CH3COONH4 and HF+HNO3+HCl were used for extraction of acid soluble, reducible, oxidizable and residual fractions of heavy metals in POC, respectively. The leaching toxicity of the POC was investigated by the USEPA 1311 TCLP method. The result showed the presence of Be, V, Cr, Ni, Cu, Zn, As, Se, Ag, Cd, Ba and Pb with levels of 5.13, 11.02, 2.65, 1.93, 45.43, 11.84, 15.07, 0, 0, 81.97 and 1.76 mg/kg, respectively, in POC. The leaching value in mg/L of As (4.56), Cu(1.05), Be (0.89), Zn(0.51), Ba(0.26), Ni (0.17), V(0.15), Cr(0.001) and Se (0.001) is found well below the standard limit of risk. Risk assessment code (RAC) analysis confirms the safe incorporation of POC in cement-based applications. Penerbit Universiti Kebangsaan Malaysia 2018-03 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/12034/1/12%20MOHAMMAD%20RAZAUL%20KARIM.pdf Mohammad Razaul Karim, and Sumiani Yusoff, and Hashim Abdul Razak, and Faisal I. Chowdhury, and Hossain Zabed, (2018) Heavy metals leaching behaviour assessment of palm oil clinker. Sains Malaysiana, 47 (3). pp. 523-530. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid47bil3_2018/KandunganJilid47Bil3_2018.html |
institution |
Universiti Kebangsaan Malaysia |
building |
Perpustakaan Tun Sri Lanang Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Kebangsaan Malaysia |
content_source |
UKM Journal Article Repository |
url_provider |
http://journalarticle.ukm.my/ |
language |
English |
description |
Technical benefit of incorporation of Palm Oil Clinker (POC) in cement-based applications has been proven in recent studies. The aim of this work was to assess the heavy metal leaching behavior to ensure environmental safety of using POC in cement-based applications. The chemical composition, morphology, total organic carbon (TOC) and mineralogy were determined using XRF, FESEM, TOC analyzers and XRD to select appropriate chemical reagents for complete digestion. HNO3, HF and HClO4 were used for digestion of POC to measure heavy metal content using ICP-MS. The chemical reagents CH3COOH, NH2OH-HCl, H2O2+CH3COONH4 and HF+HNO3+HCl were used for extraction of acid soluble, reducible, oxidizable and residual fractions of heavy metals in POC, respectively. The leaching toxicity of the POC was investigated by the USEPA 1311 TCLP method. The result showed the presence of Be, V, Cr, Ni, Cu, Zn, As, Se, Ag, Cd, Ba and Pb with levels of 5.13, 11.02, 2.65, 1.93, 45.43, 11.84, 15.07, 0, 0, 81.97 and 1.76 mg/kg, respectively, in POC. The leaching value in mg/L of As (4.56), Cu(1.05), Be (0.89), Zn(0.51), Ba(0.26), Ni (0.17), V(0.15), Cr(0.001) and Se (0.001) is found well below the standard limit of risk. Risk assessment code (RAC) analysis confirms the safe incorporation of POC in cement-based applications. |
format |
Article |
author |
Mohammad Razaul Karim, Sumiani Yusoff, Hashim Abdul Razak, Faisal I. Chowdhury, Hossain Zabed, |
spellingShingle |
Mohammad Razaul Karim, Sumiani Yusoff, Hashim Abdul Razak, Faisal I. Chowdhury, Hossain Zabed, Heavy metals leaching behaviour assessment of palm oil clinker |
author_facet |
Mohammad Razaul Karim, Sumiani Yusoff, Hashim Abdul Razak, Faisal I. Chowdhury, Hossain Zabed, |
author_sort |
Mohammad Razaul Karim, |
title |
Heavy metals leaching behaviour assessment of palm oil clinker |
title_short |
Heavy metals leaching behaviour assessment of palm oil clinker |
title_full |
Heavy metals leaching behaviour assessment of palm oil clinker |
title_fullStr |
Heavy metals leaching behaviour assessment of palm oil clinker |
title_full_unstemmed |
Heavy metals leaching behaviour assessment of palm oil clinker |
title_sort |
heavy metals leaching behaviour assessment of palm oil clinker |
publisher |
Penerbit Universiti Kebangsaan Malaysia |
publishDate |
2018 |
url |
http://journalarticle.ukm.my/12034/1/12%20MOHAMMAD%20RAZAUL%20KARIM.pdf http://journalarticle.ukm.my/12034/ http://www.ukm.my/jsm/malay_journals/jilid47bil3_2018/KandunganJilid47Bil3_2018.html |
_version_ |
1643738674317230080 |
score |
13.214268 |