Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity

Visual conditions such as anisometropia, monovision and monocular undercorrection affect the combination of visual input from both eyes. This study investigated the effects of monocular blur, in binocularly normal participants, on stereoacuity and binocular contrast sensitivity. Fifteen young adults...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd ‘Izzuddin Hairol,, Loshane Arusulem,, Wong, Jia Ying
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2017
Online Access:http://journalarticle.ukm.my/11454/1/16733-47092-1-SM.pdf
http://journalarticle.ukm.my/11454/
http://ejournal.ukm.my/jskm/issue/view/635
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ukm.journal.11454
record_format eprints
spelling my-ukm.journal.114542018-03-16T00:49:42Z http://journalarticle.ukm.my/11454/ Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity Mohd ‘Izzuddin Hairol, Loshane Arusulem, Wong, Jia Ying Visual conditions such as anisometropia, monovision and monocular undercorrection affect the combination of visual input from both eyes. This study investigated the effects of monocular blur, in binocularly normal participants, on stereoacuity and binocular contrast sensitivity. Fifteen young adults (age range between 19 and 23 years old) with normal visual acuity and binocular vision participated in this study. Stereopsis was measured using the TNO test with a series of positive spherical lenses placed before the dominant eye. The procedure was repeated using the Titmus Stereotest on five participants as a control experiment. Monocular and binocular contrast sensitivities were also measured using the Pelli-Robson Contrast Sensitivity Chart. Blur was induced monocularly with a series of positive spherical lenses placed before the dominant eye and binocular contrast sensitivity was re-measured. Stereopsis scores decreased significantly when monocular blur was imposed. Across blur levels, absolute stereopsis scores measured with TNO test were worse than those measured with Titmus stereotest (all p < 0.05). However, the ratio of scores obtained without blur and under monocular blur appeared to be similar for both tests. Stereopsis without blur was between 6.82× to 8× better than that obtained with the highest level of imposed monocular blur. Binocular contrast sensitivity score decreased significantly with increasing level of monocular blur (p < 0.01). Binocular contrast sensitivity score without blur was 1.62× better than that obtained under binocular viewing with highest level of imposed blur. Stereopsis tests are more sensitive than measurements of binocular contrast sensitivity as an indicator of interocular acuity discrepancies which could occur in anisometropic or monovision patients. However, the choice of stereopsis test is crucial, as the TNO test appears to be more sensitive to monocular blur than the Titmus stereostest. Penerbit Universiti Kebangsaan Malaysia 2017 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/11454/1/16733-47092-1-SM.pdf Mohd ‘Izzuddin Hairol, and Loshane Arusulem, and Wong, Jia Ying (2017) Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity. Jurnal Sains Kesihatan Malaysia, 15 (1). pp. 19-25. ISSN 1675-8161 http://ejournal.ukm.my/jskm/issue/view/635
institution Universiti Kebangsaan Malaysia
building Perpustakaan Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description Visual conditions such as anisometropia, monovision and monocular undercorrection affect the combination of visual input from both eyes. This study investigated the effects of monocular blur, in binocularly normal participants, on stereoacuity and binocular contrast sensitivity. Fifteen young adults (age range between 19 and 23 years old) with normal visual acuity and binocular vision participated in this study. Stereopsis was measured using the TNO test with a series of positive spherical lenses placed before the dominant eye. The procedure was repeated using the Titmus Stereotest on five participants as a control experiment. Monocular and binocular contrast sensitivities were also measured using the Pelli-Robson Contrast Sensitivity Chart. Blur was induced monocularly with a series of positive spherical lenses placed before the dominant eye and binocular contrast sensitivity was re-measured. Stereopsis scores decreased significantly when monocular blur was imposed. Across blur levels, absolute stereopsis scores measured with TNO test were worse than those measured with Titmus stereotest (all p < 0.05). However, the ratio of scores obtained without blur and under monocular blur appeared to be similar for both tests. Stereopsis without blur was between 6.82× to 8× better than that obtained with the highest level of imposed monocular blur. Binocular contrast sensitivity score decreased significantly with increasing level of monocular blur (p < 0.01). Binocular contrast sensitivity score without blur was 1.62× better than that obtained under binocular viewing with highest level of imposed blur. Stereopsis tests are more sensitive than measurements of binocular contrast sensitivity as an indicator of interocular acuity discrepancies which could occur in anisometropic or monovision patients. However, the choice of stereopsis test is crucial, as the TNO test appears to be more sensitive to monocular blur than the Titmus stereostest.
format Article
author Mohd ‘Izzuddin Hairol,
Loshane Arusulem,
Wong, Jia Ying
spellingShingle Mohd ‘Izzuddin Hairol,
Loshane Arusulem,
Wong, Jia Ying
Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity
author_facet Mohd ‘Izzuddin Hairol,
Loshane Arusulem,
Wong, Jia Ying
author_sort Mohd ‘Izzuddin Hairol,
title Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity
title_short Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity
title_full Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity
title_fullStr Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity
title_full_unstemmed Effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity
title_sort effects of monocular blur on clinical measurements of stereopsis and binocular contrast sensitivity
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2017
url http://journalarticle.ukm.my/11454/1/16733-47092-1-SM.pdf
http://journalarticle.ukm.my/11454/
http://ejournal.ukm.my/jskm/issue/view/635
_version_ 1643738500183359488
score 13.18916