Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants

Background: Strength testing is one of the primary assessment tools for physical strength examination, and an increase in strength is the aim of many rehabilitation programs. Manual muscle testing (MMT) is the most commonly used strength testing method in clinical settings. It is a subjective measur...

Full description

Saved in:
Bibliographic Details
Main Authors: S.J., Kanimozhiselvi, M., Sindhuja, J., Radhika
Format: Article
Language:English
Published: INTI International University 2023
Subjects:
Online Access:http://eprints.intimal.edu.my/1788/1/ij2023_39.pdf
http://eprints.intimal.edu.my/1788/
https://intijournal.intimal.edu.my
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-inti-eprints.1788
record_format eprints
spelling my-inti-eprints.17882023-09-13T09:50:59Z http://eprints.intimal.edu.my/1788/ Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants S.J., Kanimozhiselvi M., Sindhuja J., Radhika Q Science (General) QP Physiology Background: Strength testing is one of the primary assessment tools for physical strength examination, and an increase in strength is the aim of many rehabilitation programs. Manual muscle testing (MMT) is the most commonly used strength testing method in clinical settings. It is a subjective measurement technique whereby the tester applies resistance to a maximum voluntary muscle contraction. The reliability of the Fitmust hand-held dynamometer is not previously reported in the literature. Aims and Objectives: The study aims to test the reliability of the Fitmust hand-held dynamometer for lower limb muscles in comparison with the Jamar Hand Held dynamometer. Methods: Maximum voluntary isometric contraction of hip extension, knee extension, and plantar flexion is measured by two different therapists on different days using fit must hand-held dynamometer for 40 healthy participants of age category 18- 30 years. Result: Reliability was evaluated by computing Intra-class Correlation Coefficients (ICC), which analyse the consistency between two or more quantitative measures, and Cronbach's Alpha which measured agreement. Conclusion: Inter-tester reliability data obtained for Assessor 1 and 2 were consistent for knee measurements. However, data for the hip and ankle varied considerably. Assessors 1 and 2 demonstrated a 'moderate to excellent' association for knee Measurements. INTI International University 2023-09 Article PeerReviewed text en cc_by_4 http://eprints.intimal.edu.my/1788/1/ij2023_39.pdf S.J., Kanimozhiselvi and M., Sindhuja and J., Radhika (2023) Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants. INTI JOURNAL, 2023 (39). pp. 1-7. ISSN e2600-7320 https://intijournal.intimal.edu.my
institution INTI International University
building INTI Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider INTI International University
content_source INTI Institutional Repository
url_provider http://eprints.intimal.edu.my
language English
topic Q Science (General)
QP Physiology
spellingShingle Q Science (General)
QP Physiology
S.J., Kanimozhiselvi
M., Sindhuja
J., Radhika
Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants
description Background: Strength testing is one of the primary assessment tools for physical strength examination, and an increase in strength is the aim of many rehabilitation programs. Manual muscle testing (MMT) is the most commonly used strength testing method in clinical settings. It is a subjective measurement technique whereby the tester applies resistance to a maximum voluntary muscle contraction. The reliability of the Fitmust hand-held dynamometer is not previously reported in the literature. Aims and Objectives: The study aims to test the reliability of the Fitmust hand-held dynamometer for lower limb muscles in comparison with the Jamar Hand Held dynamometer. Methods: Maximum voluntary isometric contraction of hip extension, knee extension, and plantar flexion is measured by two different therapists on different days using fit must hand-held dynamometer for 40 healthy participants of age category 18- 30 years. Result: Reliability was evaluated by computing Intra-class Correlation Coefficients (ICC), which analyse the consistency between two or more quantitative measures, and Cronbach's Alpha which measured agreement. Conclusion: Inter-tester reliability data obtained for Assessor 1 and 2 were consistent for knee measurements. However, data for the hip and ankle varied considerably. Assessors 1 and 2 demonstrated a 'moderate to excellent' association for knee Measurements.
format Article
author S.J., Kanimozhiselvi
M., Sindhuja
J., Radhika
author_facet S.J., Kanimozhiselvi
M., Sindhuja
J., Radhika
author_sort S.J., Kanimozhiselvi
title Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants
title_short Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants
title_full Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants
title_fullStr Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants
title_full_unstemmed Inter Tester Reliability of Fitmust Hand Held Dynamometer among Healthy Participants
title_sort inter tester reliability of fitmust hand held dynamometer among healthy participants
publisher INTI International University
publishDate 2023
url http://eprints.intimal.edu.my/1788/1/ij2023_39.pdf
http://eprints.intimal.edu.my/1788/
https://intijournal.intimal.edu.my
_version_ 1778167414299557888
score 13.212271