Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT

Electrical Capacitance Tomography (ECT) is a popular technique for multi-phase fluidic imaging. For the sake of better microfluidics handling within a miniaturized platform, this paper presents a simulation study of a lab-on-chip 3D ECT model with two set of 8-planar-electrode arrays position circul...

全面介绍

Saved in:
书目详细资料
Main Authors: Hor, Xian Feng, Leow, Pei Ling, Mohamed Ali, Mohamed Sultan, Mohammad Din, Shahrulnizahani, Puspanathan, Jaysuman, Zulkiflli, Nur Amira, Abdul Rahim, Ruzairi
格式: Conference or Workshop Item
语言:English
出版: 2019
主题:
在线阅读:http://eprints.utm.my/id/eprint/89845/1/HorXianFeng2019_SimulationStudyofTwoPhaseFluid3D.pdf
http://eprints.utm.my/id/eprint/89845/
http://dx.doi.org/10.1109/ICSIPA45851.2019.8977750
标签: 添加标签
没有标签, 成为第一个标记此记录!
id my.utm.89845
record_format eprints
spelling my.utm.898452021-03-04T02:47:23Z http://eprints.utm.my/id/eprint/89845/ Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT Hor, Xian Feng Leow, Pei Ling Mohamed Ali, Mohamed Sultan Mohammad Din, Shahrulnizahani Puspanathan, Jaysuman Zulkiflli, Nur Amira Abdul Rahim, Ruzairi TK Electrical engineering. Electronics Nuclear engineering Electrical Capacitance Tomography (ECT) is a popular technique for multi-phase fluidic imaging. For the sake of better microfluidics handling within a miniaturized platform, this paper presents a simulation study of a lab-on-chip 3D ECT model with two set of 8-planar-electrode arrays position circularly on the top and bottom layer of the sensing microchamber. The presented simulation studies are to reconstruct the 3D images of a square phantom (water) in a background (air) with different location by using Linear Backward Propagation (LBP) as the image reconstruction algorithm. The simulation results have shown that the proposed lab-on-chip 3D ECT is capable to identify the different position of the phantom. 2019 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/89845/1/HorXianFeng2019_SimulationStudyofTwoPhaseFluid3D.pdf Hor, Xian Feng and Leow, Pei Ling and Mohamed Ali, Mohamed Sultan and Mohammad Din, Shahrulnizahani and Puspanathan, Jaysuman and Zulkiflli, Nur Amira and Abdul Rahim, Ruzairi (2019) Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT. In: 2019 IEEE International Conference on Signal and Image Processing Applications, ICSIPA 2019, 17 September 2019 - 19 September 2019, Kuala Lumpur, Malaysia. http://dx.doi.org/10.1109/ICSIPA45851.2019.8977750
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Hor, Xian Feng
Leow, Pei Ling
Mohamed Ali, Mohamed Sultan
Mohammad Din, Shahrulnizahani
Puspanathan, Jaysuman
Zulkiflli, Nur Amira
Abdul Rahim, Ruzairi
Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT
description Electrical Capacitance Tomography (ECT) is a popular technique for multi-phase fluidic imaging. For the sake of better microfluidics handling within a miniaturized platform, this paper presents a simulation study of a lab-on-chip 3D ECT model with two set of 8-planar-electrode arrays position circularly on the top and bottom layer of the sensing microchamber. The presented simulation studies are to reconstruct the 3D images of a square phantom (water) in a background (air) with different location by using Linear Backward Propagation (LBP) as the image reconstruction algorithm. The simulation results have shown that the proposed lab-on-chip 3D ECT is capable to identify the different position of the phantom.
format Conference or Workshop Item
author Hor, Xian Feng
Leow, Pei Ling
Mohamed Ali, Mohamed Sultan
Mohammad Din, Shahrulnizahani
Puspanathan, Jaysuman
Zulkiflli, Nur Amira
Abdul Rahim, Ruzairi
author_facet Hor, Xian Feng
Leow, Pei Ling
Mohamed Ali, Mohamed Sultan
Mohammad Din, Shahrulnizahani
Puspanathan, Jaysuman
Zulkiflli, Nur Amira
Abdul Rahim, Ruzairi
author_sort Hor, Xian Feng
title Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT
title_short Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT
title_full Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT
title_fullStr Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT
title_full_unstemmed Simulation study of two-phase fluid 3D imaging using lab-on-chip ECT
title_sort simulation study of two-phase fluid 3d imaging using lab-on-chip ect
publishDate 2019
url http://eprints.utm.my/id/eprint/89845/1/HorXianFeng2019_SimulationStudyofTwoPhaseFluid3D.pdf
http://eprints.utm.my/id/eprint/89845/
http://dx.doi.org/10.1109/ICSIPA45851.2019.8977750
_version_ 1693725954381185024
score 13.250246