Modeling steam generator system of pressurized water reactor using fuzzy arithmetic

Steam generator system is known as the bridge between the primary and secondary systems for phase changes from water into steam. The aim of this paper is to identify the best input that influence the steam generator system in the process of changing from water to steam, to ensure the process is effi...

全面介紹

Saved in:
書目詳細資料
Main Authors: Wan Mohamad, W. M., Ahmad, T., Ashaari, A.
格式: Conference or Workshop Item
出版: Springer Verlag 2016
主題:
在線閱讀:http://eprints.utm.my/id/eprint/73582/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84989345509&doi=10.1007%2f978-981-10-2777-2_21&partnerID=40&md5=bae16ba02df45ecc7c1bddd8b13ecca9
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:Steam generator system is known as the bridge between the primary and secondary systems for phase changes from water into steam. The aim of this paper is to identify the best input that influence the steam generator system in the process of changing from water to steam, to ensure the process is efficient. The method consists of the transformation method of fuzzy arithmetic which is to compute the measure of influence for each parameter in the model system. The result is then verified against simulation and analysis.