The power level control of a pressurised water reactor nuclear power plant

The control system of a reactor core in a Nuclear Power Plant (NPP) is non-trivial to ensure safe operation of a nuclear power plant. Owing to the complex and non-linear characteristics of a nuclear power plant, it is, therefore, essential to control the power in load following condition through the...

詳細記述

保存先:
書誌詳細
主要な著者: Mahendra Kumar, Jothi Letchumy, Anwar, P. P. Abdul Majeed, Muhammad Aizzat, Zakaria, Mohd Azraai, Mohd Razman, Ismail, Mohd Khairuddin
フォーマット: Conference or Workshop Item
言語:English
出版事項: Springer, Singapore 2020
主題:
オンライン・アクセス:http://umpir.ump.edu.my/id/eprint/27729/1/The%20power%20level%20control%20of%20a%20pressurised%20water%20reactor%20.pdf
http://umpir.ump.edu.my/id/eprint/27729/
https://doi.org/10.1007/978-981-13-9539-0_43
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
その他の書誌記述
要約:The control system of a reactor core in a Nuclear Power Plant (NPP) is non-trivial to ensure safe operation of a nuclear power plant. Owing to the complex and non-linear characteristics of a nuclear power plant, it is, therefore, essential to control the power in load following condition through the regulation of the reactor core. The aim of this paper is to evaluate the efficacy of different variation of classical control schemes, namely, P, PI, PD and PID to control the power level output. The reactor core model is based on the H.B. Robinson Pressurised Water Reactor NPP. The control schemes evaluated were tuned based on the Ziegler-Nichols tuning method. It was demonstrated through the following simulation investigation that the PID control scheme is appropriate in regulating the power level.