Search Results - parallel 3- cooling

Search alternatives:

Refine Results
  1. 1

    Experimental analysis of SiO2-distilled water nanofluids in a polymer electrolyte membrane fuel cell parallel channel cooling plate by Irnie Azlin, Zakaria, Wan Ahmad Najmi, Wan Mohamed, Zailan, M. B., Azmi, W. H.

    Published 2019
    “…SiO2 nanoparticles were dispersed in distilled water at 0.1%, 0.3% and 0.5% volume concentrations and tested in a parallel channel cooling plate system. …”
    Get full text
    Get full text
    Get full text
    Article
  2. 2
  3. 3
  4. 4

    Low Power Heater Design On Flexible Printed Circuit Board For Incubator Application by Hashim, Solehah Md

    Published 2018
    “…The heater is fabricated at QDOS Technology Sdn Bhd. Three tests are conducted which are; 1) Functionality test of single heater, series heater and parallel heater, 2) Series and parallel heater with and without fan test in the incubator, 3) Series and parallel heater with and without fan test using switching control system in incubator. …”
    Get full text
    Get full text
    Thesis
  5. 5

    Performance Enhancement of Solar PV Panels Using Splash Fill Cooling under Tropical Conditions by Risna, Daniar, Muhammad, Basyir, Arsy Febrina, Dewi, Aidi, Finawan, Yaman, ., Yassir, ., Muhammad, Ramzil

    Published 2026
    “…Two identical 50 Wp PV modules were tested in parallel, with one equipped with the splash fill cooling system and the other serving as a reference without cooling. …”
    Get full text
    Get full text
    Get full text
    Get full text
    Article
  6. 6

    Intelligent Manufacturing And Energy Sustainability by Ismail, Mohd Azmi

    Published 2020
    “…The performances of 1,4, and 9 number of nozzles under horizontal parallel, counter, and vertical flow arrangement have been experimentally analyzed for air volume flow rate from 0.34 to 2.15 m3/s, room temperature from 28.5 to 30.2 °C, and relative humidity between 59 and 78%. …”
    Get full text
    Get full text
    Monograph
  7. 7

    Effect of nozzle angle on jet impingement cooling system by Khaider, Abu Bakar

    Published 2009
    “…Those studies are needed parallel to the current researchers endeavor for future development of cooling system in global industries. …”
    Get full text
    Get full text
    Undergraduates Project Papers
  8. 8

    Thermal Analysis On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate by Irnie, Zakaria, W. A. N. W., Mohamed, A. M. I., Mamat, R., Saidur, Azmi, W. H., R., Mamat, K. I., Sainan, H., Ismail

    Published 2015
    “…Numerical analysis of thermal enhancement for a single Proton Exchange Membrane Fuel Cell (PEMFC) cooling plate is presented in this paper. A low concentration of Al2O3 in Water - Ethylene Glycol mixtures was used as coolant in 220mm x 300mm cooling plate with 22 parallel mini channels of 1 x 5 x 100mm. …”
    Get full text
    Get full text
    Get full text
    Article
  9. 9
  10. 10
  11. 11

    Numerical Study On Heat Transfer Enhancement And Fluid Flow for Low Concentration of Al2O3 Water - Ethylene Glycol Mixture Nanofluid in A Single PEMFC Cooling Plate by Irnie, Zakaria, W. A. N., W. Mohamed, A. M. I., Mamat, R., Saidur, Azmi, W. H., R., Mamat, K. I., Sainan

    Published 2015
    “…Numerical analysis on thermal enhancement for a single Proton Exchange Membrane Fuel Cell (PEMFC) cooling plate is presented in this paper. In this study, low concentration of Al2O3 in Water - Ethylene Glycol mixtures was used as coolant in 220mm x 300mm cooling plate with 22 parallel mini channels of 1 x 5 x 100mm. …”
    Get full text
    Get full text
    Get full text
    Get full text
    Article
  12. 12

    Thermal Analysis of Al2O3–water Ethylene Glycol Mixture Nanofluid for Single PEM Fuel Cell Cooling Plate: An Experimental Study by Irnie, Zakaria, Azmi, W. H., A. M. I., Mamat, R., Mamat, R. , Saidur, S. F., Abu Talib, W. A. N., W. Mohamed

    Published 2016
    “…The study was conducted in a cooling plate with 22 parallel mini channels and large fluid distributors under constant heat load of 100 W. …”
    Get full text
    Get full text
    Get full text
    Article
  13. 13

    CFD study of coolant for battery thermal management system by Muhamad Zin, Muhammad Shahir

    Published 2022
    “…Characterization of nanofluid is focused first to study the effect of different type of nanofluid on the resultant temperature, with 4% A12O3-water nanofluid (Case 51)displayed the best cooling capabilities despite having Mouromtseff number of 1,08 at Reynolds number of 2300, lower than some other nanofluid described in this study. …”
    Get full text
    Get full text
    Get full text
    Get full text
    Thesis
  14. 14

    An economic analysis of a solar assisted heat pump system for cooling, water heating and drying by Hawlader, Mohammad Nurul Alam, Shaochun, Ye

    Published 2011
    “…The presence of evaporator-collector, which is in parallel connection with the room evaporator, enables the system to operate round the clock. …”
    Get full text
    Get full text
    Get full text
    Proceeding Paper
  15. 15

    Performance comparison of series and parallel damped LCL filters using 5-level voltage source converter by Shanono, Ibrahim Haruna, Nor Rul Hasma, Abdullah, Hamdan, Daniyal, Aisha, Muhammad

    Published 2020
    “…Hence, this paper designs and compares the total harmonic distortion (THD) and efficiency values of three set of filters, namely LCL filter, LCL with series and parallel resistance on a novel five-level multilevel voltage source inverter topology. …”
    Get full text
    Get full text
    Get full text
    Article
  16. 16

    Thermal performance improvement for residential buildings in the tropics through the application of green façade and green roof by Abass Younis, Fatma Hussien

    Published 2021
    “…On the other hand, the correlation between the annual cooling loads and corresponding OTTV for residential buildings revealed a strong relationship between the annual cooling load and the OTTV amount. …”
    Get full text
    Get full text
    Get full text
    Get full text
    Thesis
  17. 17

    Enhancing Photovoltaic-Thermoelectric Generator (PV-TEG) system performance via mathematical modeling and advanced thermal interface material: An emphasis on Pyrolytic graphite She... by Mahmoud AL Shurafa S., Basim Ismail F., Kazem H.A., Ee Sann T., Abdel Hameed Almajali T.

    Published 2025
    “…The paper assessed the effectiveness of a Pyrolytic Graphite Sheet (PGS) as a Thermal Interface Material (TIM) in PV-TEG systems and three cooling approaches. The investigation explores two configurations (parallel and bent) of PGS and five TIM materials. …”
    Article
  18. 18

    Theoretical and experimental simulation of roof-top bus multiple-circuit air-conditioning system performance by Mansour, M. Khamis, Musa, Md. Nor, Hassan, M. N. W., Abdullah, H.

    Published 2007
    “…Many air-conditioning (AC) systems are designed to operate at maximum cooling capacity regardless of the variation in the daily cooling load. …”
    Get full text
    Get full text
    Article
  19. 19

    Hybrid Solar/Heat Pipe/Water Heater by Lau, Jin Yik

    Published 2015
    “…The experiment result showed that water can be heated with a temperature difference of around 0.3C – 7.6C.…”
    Get full text
    Get full text
    Final Year Project / Dissertation / Thesis
  20. 20

    Entrance and exit effects on oscillatory flow within parallel-plates in standing-wave thermoacoustic system with two different operating frequencies by Mohd Sa'at, Fatimah Al-Zahrah, Allafi, Waleed Almukhtar

    Published 2022
    “…Two different operating frequencies of 14.2 Hz and 23.6 Hz were studied for flow with five different amplitudes that were represented using drive ratios of 0.3%, 0.83%, 1.5%, 2.1% and 3%. These correspond to cases with Reynolds numbers between 5936 and 62926. …”
    Get full text
    Get full text
    Get full text
    Article