Search Results - all grid array

Refine Results
  1. 1
  2. 2

    A multi-input converter for hybrid photovoltaic array/wind turbine/fuel cell and battery storage system connected AC grid network by Rosli, M.A., Yahaya, N.Z., Baharudin, Z.

    Published 2014
    “…The paper is to propose a multi-input power converter (MIPC) for hybrid photovoltaic (PV) array, wind turbine (WT), fuel cell (FC) and battery storage (BT) connected AC grid network. …”
    Get full text
    Get full text
    Conference or Workshop Item
  3. 3

    Grid-based simultaneous localization and mapping using Rao-blackwellized particle filter with neural network for mini robots / Norhidayah Mohamad Yatim by Mohamad Yatim, Norhidayah

    Published 2018
    “…This research aims to develop such capability known as Simultaneous Localization and Mapping (SLAM) algorithm for mini robots with array of infrared (IR) sensors. Existing methods had implemented either feature-based or occupancy grid map (OG) as map representation. …”
    Get full text
    Get full text
    Thesis
  4. 4
  5. 5

    An improved model for output power of grid-connected photovoltaic system under Malaysian climate / Noorfarhana Mat Yusoff by Mat Yusoff, Noorfarhana

    Published 2018
    “…Therefore, this study presents the development of a new de-rating factor of output power prediction for grid-connected photovoltaic (GCPV) system in Malaysian climate due to PV array mounting type. …”
    Get full text
    Get full text
    Thesis
  6. 6
  7. 7

    Mounting configuration factor for building integrated photovoltaic and retrofitted grid-connected photovoltaic system / Noor Farhana Yusoff ... [et al.]. by Yusoff, Noor Farhana, Zakaria, Nor Zaini, Zainuddin, Hedzlin, Shaari, Sulaiman

    Published 2017
    “…Data for PV module temperature, ambient temperature, plane-of-array solar irradiance and AC power were logged at 5-min interval for all systems. …”
    Get full text
    Get full text
    Get full text
    Article
  8. 8

    Design and control of large-scale grid-connected photovoltaic power plant with fault ride-through by Al-Shetwi, Ali Qasem Saleh

    Published 2019
    “…Furthermore, to keep the power balance between both sides of the inverter, PV array can generate a possible amount of active power according to the rating of grid inverter and voltage sag depth by operating in two modes, which are normal and FRT modes. …”
    Get full text
    Get full text
    Thesis
  9. 9
  10. 10

    Analysis of photovoltaic panels performance and power output forecasting based on optimized deep learning technique / Muhammad Naveed Akhter by Muhammad Naveed, Akhter

    Published 2021
    “…Performance analysis findings show that p-si PV system performs better with a higher annual average (array yield (1309.7 h), array efficiency (12.17 %), and system efficiency (11.33 %)) accompanied by less degradation in almost all performance parameters compared to a-si and m-si PV systems. …”
    Get full text
    Get full text
    Get full text
    Thesis
  11. 11

    Design of a PV-diesel hybrid system with unreliable grid connection in Kampung Lb Johnson Village, Malaysia by Almajdup, Salleh A.A

    Published 2018
    “…Secondly,the choosing of the proposed components of the system parts are also performed which includes PV arrays, diesel generators,fuel prices,battery banks and system power convertor.Thirdly,the pre-design step which includes finding all possible,existing and prospective scenarios are designed and prepared.Finally,the simulation of all of the proposed designs are carried out in deep details using HOMER software.The performance of all systems is driven based on deep analysis of all technical,economical,and environmental aspects.In addition,each system is compared to all other systems in order to find the optimal design with respect to the current existing diesel generator/grid system.Meanwhile, four different systems were choosing which includes.The existing diesel generator/grid,PV /battery/grid,PV/diesel generator/battery,PV/battery,and PV/diesel generator/battery/grid hybrid system.The result indicates that the PV/diesel generator/battery/grid hybrid system shows the best behaviour,sizing efforts,techno-economic, and a very good environmental performance over all systems.This system is choosing to be the optimal system by including the best Net Present Cost (NPC) RM6341312.46 and a very good Cost of Energy (COE) 1.226 RM/kWb,and seem to be promising for updating the current standalone (unreliable) systems.However,although the PV/diesel generator/battery/grid scenario shows a very good environmental performance,the 100% renewable energy system (PV /battery) trends to have the best environmental effects towards the surrounding environment by realising zero C02 emissions.Unfortunately,the PV /battery scenario have the highest NPC and COE.The results also informed that using hybrid system in power generation and updating the unreliable standalone mini-grid system would result in improving the general performance of the system,reducing the fuel consummation, fuel cost,and harmful C02 emissions.However,due to the current high prices of the renewable energy systems such as PV and batteries,the total replacement of the existing system seems to be economically impractical.But,the current developed technology seems to be promising to reduce these prices in the near future.…”
    Get full text
    Get full text
    Get full text
    Get full text
    Thesis
  12. 12
  13. 13
  14. 14

    A community scale hybrid renewable energy system for sustainable power supply during load shedding by Bakht, Muhammad Paend, Haji Mohd, Mohd Norzali, Md. Ayob, Shahrin, Khan, Nuzhat, Bukar, Abba Lawan

    Published 2023
    “…Load shedding is an operating condition in which the electrical grid is temporarily disconnected from the load. The objective is to minimize the gap between available generation capacity and load demand while maintaining an equitable supply for all consumers. …”
    Get full text
    Get full text
    Get full text
    Article
  15. 15

    Xilinx FPGA based three-phase PWM inverter and its application for utility connected PV system by Mekhilef, Saad, Rahim, N.A.

    Published 2002
    “…The techniques developed and presented in this paper are readily applicable to other currently available Xilinx chips.Simulation and hardware results of a new solar photovoltaic inverter configuration interconnected to the grid are presented. From the simulation and experimental results it is confirmed that the harmonic distortion of the output current waveform of the inverter fed to the grid is within the stipulated limits laid down by the utility companies.…”
    Get full text
    Get full text
    Get full text
    Conference or Workshop Item
  16. 16

    A PI based coordinated maximum power point tracking controller for grid connected photovoltaic system / Md Haidar Islam by Md Haidar, Islam

    Published 2021
    “…Photovoltaic (PV) sources are predicted to become one of the biggest contributors to electricity generation among all renewable energy generation candidates by 2040. …”
    Get full text
    Get full text
    Get full text
    Thesis
  17. 17

    Ionic contaminations level and cleaning flip chip BGA package via a new cleaning solvent technology by Kar Y.B., Talik N.A., Sauli Z., Seng F.C., Yong T.C., Retnasamy V.

    Published 2023
    “…Purpose - This paper aims to discuss the effects of ionic contaminations on the die surface of high lead flip chip ball grid array (FCBGA) package. Ionic contaminations from the flux residue, formed during the die attachment process, could affect the package long-term performance. …”
    Article
  18. 18
  19. 19

    A community scale hybrid renewable energy system for sustainable power supply during load shedding by Muhammad Paend Bakht, Muhammad Paend Bakht, Mohd Norzali Haji Mohd, Mohd Norzali Haji Mohd, Shahrin Md. Ayob, Shahrin Md. Ayob, Nuzhat Khan, Nuzhat Khan, Abba Lawan Bukar, Abba Lawan Bukar

    Published 2023
    “…Load shedding is an operating condition in which the electrical grid is temporarily disconnected from the load. The objective is to minimize the gap between available generation capacity and load demand while maintaining an equitable supply for all consumers. …”
    Get full text
    Get full text
    Get full text
    Article
  20. 20

    A community scale hybrid renewable energy system for sustainable power supply during load shedding by Muhammad Paend Bakh, Muhammad Paend Bakh, Haji Mohd, Mohd Norzali, Md. Ayob, Shahrin, Nuzhat Khan, Nuzhat Khan, Abba Lawan Bukar, Abba Lawan Bukar

    Published 2023
    “…Load shedding is an operating condition in which the electrical grid is temporarily disconnected from the load. The objective is to minimize the gap between available generation capacity and load demand while maintaining an equitable supply for all consumers. …”
    Get full text
    Get full text
    Get full text
    Article