Search Results - ((reconstruction algorithm) OR (detection algorithm))
Search alternatives:
- reconstruction algorithm »
-
1
Quantitative analysis evaluation of image reconstruction algorithms between digital and analog PET-CT
Published 2023“…Results demonstrate that both OSEM and HYPER DPR reconstruction algorithms in digital PET-CT has greater spatial resolution, increased detection sensitivity and less image noise when compared to analog PET-CT. …”
Get full text
Get full text
Article -
2
Development of computer aided three-dimensional geometric modeler based on designer's idea in twodimensional
Published 2006“…This study has proposed better solutions in terms of an enhanced thinning algorithm, a modified Freeman chain code and Vertex chain code algorithm as picture description language, and a new computational algorithm and neural network classifier for corner detection. …”
Get full text
Get full text
Monograph -
3
Enhanced algorithms for three-dimensional object interpreter
Published 2004“…The aim of this study is to propose enhanced algorithms to be used to interpret and reconstruct a sketch, and then to produce a threedimensional model. …”
Get full text
Get full text
Get full text
Thesis -
4
LEVEL-BASED CORRESPONDENCE APPROACH TO COMPUTATIONAL STEREO
Published 2010“…By comparing current local correspondence method and discussing their weakness and strength, this research tries to enhance an algorithm to improve previous works to achieve fast detection, less costly and acceptable accuracy to meet the requirement of reconstruction. …”
Get full text
Get full text
Thesis -
5
Analysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Device
Published 2024Subjects:Article -
6
Charge-coupled device based on optical tomography system for monitoring two-phase flow
Published 2024Subjects:Article -
7
CT reconstruction algorithm and low contrast detectability of phantom study: a systematic review and meta-analysis
Published 2022“…Methods: In this study, a systematic review and a meta-analysis study were conducted on CT phantom for resolution study especially based on the low contrast detectability (LCD). Furthermore, the association between the CT parameter such as tube voltage and the type of reconstruction algorithm, the amount of phantom scanning affecting the image quality and the exposure dose were also investigated in this study. …”
Get full text
Get full text
Article -
8
Shape Reconstruction using Overset Grid Generation Method with an Iterative Inversion Technique
Published 2020“…The reconstruction results demonstrated that the FBTS technique utilizing OGG-FDTD method has the ability to detect and reconstructed embedded object.…”
Get full text
Get full text
Get full text
Thesis -
9
Extraction and reconstruction of retinal vasculature
Published 2007“…This paper presents the development of an image processing algorithm for detecting and reconstructing retinal vasculature. …”
Get full text
Get full text
Get full text
Citation Index Journal -
10
Image reconstruction for solid profile measurement in ERT using non-invasive approach
Published 2017“…Image reconstruction software and its image reconstruction algorithm are an important step towards constructing a tomography system. …”
Get full text
Get full text
Get full text
Article -
11
Qualitative and quantitative accuracy evaluation of 18f-fdg PET/CT with TOF and NON-TOF system on beta value in BPL reconstruction
Published 2024“…Q.Clear, a Bayesian Penalised Likelihood (BPL) algorithm, has demonstrated notable advancements in clinical image quality and quantification, particularly in detecting subtle abnormalities. …”
Get full text
Get full text
Monograph -
12
Natural images contour segmentation / Khairul Adilah Ahmad, Sharifah Lailee Syed Abdullah and Mahmod Othman
Published 2017“…Second step is the adoption of Laplacian of Gaussian edge detection and a new corner template detection algorithm for adjustment of the pixels along the edge map in the interpolation process. …”
Get full text
Get full text
Get full text
Article -
13
PeerMate: a malicious peer detection algorithm for P2P systems based on MSPCA
Published 2012“…Firstly, we divide the malicious peers into six categories; secondly, we bring forward PeerMate, a malicious peers detection algorithm based on Multiscale Principal Component Analysis (MSPCA) and Quality of Reconstruction (QR), to detect malicious peers in reputation based P2P systems; finally, we show through simulations that PeerMate can detect malicious peers efficiently and accurately.…”
Get full text
Get full text
Get full text
Proceeding Paper -
14
Blotch removal using multi-level scanning, shape analysis, and meta heuristic techniques
Published 2015“…This post processing algorithm was provided based on a multi-level scanning and shape analysis which was presented for the better performance of high correct detection and lower false alarms for each given threshold. …”
Get full text
Get full text
Thesis -
15
2-D Reconstruction of Breast Image Using Forward-Backward Time-Stepping Method for Breast Tumour Detection
Published 2012“…In this paper, time-domain inverse-scattering technique referred to as Forward-Backward Time-Stepping (FBTS) method is applied to microwave imaging breast cancer detection. The FBTS algorithm is implemented in C++ language executed in a single computer by developing the time domain form of the FDTD. …”
Get full text
Get full text
Proceeding -
16
Sketch-based 3D modeling of symmetric objects from wireframe sketches on paper
Published 2016“…Feature extraction is a preliminary step before 3D reconstruction and therefore, a junction detection algorithm is proposed. …”
Get full text
Get full text
Thesis -
17
Compressed Sensing Implementations For Sparse Channel Estimation In OFDM Systems
Published 2018“…Fusing different reconstruction algorithms may result in the probability of fusing several incorrectly estimated indices over noisy channels. …”
Get full text
Get full text
Thesis -
18
Energy detection for spectrum sensing in OFDM-based cooperative and non-cooperative radio networks
Published 2018“…This algorithm can also work for big number of SUs that detect the OFDM signal. …”
Get full text
Get full text
Thesis -
19
Single Frame Profilometry With Rapid Phase Demodulation On Colour-Coded Fringes
Published 2019“…The phase error compensation algorithm was also proven to reduce phase errors at reference level from (1.08 ± 2.32) % to (0.73 ± 0.46) % with a 95% confidence level for 8 iterations on average, producing a visually smoother reconstructed surface. …”
Get full text
Get full text
Thesis -
20
