    A high-performance control scheme for photovoltaic pumping system under sudden irradiance and load changes by Talbi, Billel, Krim, Fateh, Rekioua, Toufik, Mekhilef, Saad, Laib, Abdelbaset, Belaout, Abdesslam

    Published 2018
    “…The PV generator-side boost converter performs the maximum power point tracking (MPPT), while the IM−side two-level inverter regulates the net DC-link voltage and the developed electromagnetic torque by IM, which is coupled with a centrifugal pump. An improved variable step size perturb and observe (P&O) algorithm is proposed to reduce the steady-state PV power fluctuation, to accelerate the tracking operation under sudden irradiance changes, and to protect IM under load drops. …”
    Get full text
    Get full text
    Article
  2. 2

    Minimization of torque ripple and flux droop using optimal DTC switching and sector rotation strategy by Ahmad Tarusan, Siti Azura

    Published 2022
    “…MATLAB/Simulink software is used to simulate the proposed strategies while a complete setup system consists of a DS1104 digital signal processor (DSP)-board (to implement the DTC algorithm), Field-programmable Gate Arrays (FPGA) (to implement the blanking circuit), two-level and five-level (CHB) inverter circuit, gate driver circuit, and a 1.1 kW induction motor with 2 kW DC generator as a load is developed for testing and verification purpose. …”