Search Results - (( stability estimation using algorithm ) OR ( java implication based algorithm ))

Refine Results
  1. 1

    Novel techniques for voltage stability assessment and improvement in power system / Ismail Musirin. by Musirin, Ismail

    Published 2004
    “…Finally, a novel Reactive Power Planning R.PP) algorithm using the state-of-the-art of EP for voltage stability improvement was developed. …”
    Get full text
    Get full text
    Thesis
  2. 2

    Voltage Stability Index Calculation by Hybrid State Estimation Based on Multi Objective Optimal Phasor Measurement Unit Placement DUPLICATE by Matsukawa, Yoshiaki, Watanabe, Masayuki, Abdul Wahab, Noor Izzri, Othman, Mohammad Lutf

    Published 2019
    “…As a result of CBI estimation, HSE using PMU is relatively accurate in voltage stability index estimation compared to SCADA SE, which uses the RTU alone. …”
    Get full text
    Get full text
    Get full text
    Article
  3. 3

    Voltage stability index calculation by hybrid state estimation based on multi objective optimal phasor measurement unit placement by Matsukawa, Yoshiaki, Watanabe, Masayuki, Abdul Wahab, Noor Izzri, Othman, Mohammad Lutfi

    Published 2019
    “…As a result of CBI estimation, HSE using PMU is relatively accurate in voltage stability index estimation compared to SCADA SE, which uses the RTU alone. …”
    Get full text
    Get full text
    Get full text
    Article
  4. 4
  5. 5

    Upper Limb Joint Angle Estimation Using Wearable IMUs and Personalized Calibration Algorithm by Rahman, Md. Mahmudur, Beng Gan, Kok, Abd Aziz, Noor Azah, Huong, , Audrey, You, Huay Woon

    Published 2023
    “…Multiple trials using the proposed algorithm estimated the elbow joint angle of the rigid body with a maximum RMSE of 0.46◦ Using the IMU manufacturer’s (WitMotion) algorithm (Kalman filter), the maximum RMSE was 1.97◦ For the fourth trial, joint angles were also calculated with external acceleration, and the RMSE was 0.996◦ In all cases, the joint angles were within therapeutic limits.…”
    Get full text
    Get full text
    Get full text
    Article
  6. 6

    Upper Limb Joint Angle Estimation Using Wearable IMUs and Personalized Calibration Algorithm by Rahman, Md. Mahmudur, Gan, Kok Beng, Abd Aziz, Noor Azah, Huong, Audrey, Woon You, Huay

    Published 2023
    “…Multiple trials using the proposed algorithm estimated the elbow joint angle of the rigid body with a maximum RMSE of 0.46◦ Using the IMU manufacturer’s (WitMotion) algorithm (Kalman filter), the maximum RMSE was 1.97◦ For the fourth trial, joint angles were also calculated with external acceleration, and the RMSE was 0.996◦ In all cases, the joint angles were within therapeutic limits.…”
    Get full text
    Get full text
    Get full text
    Article
  7. 7

    Position control of robot manipulator: Design a novel SISO adaptive sliding mode fuzzy PD fuzzy sliding mode control. by Sulaiman, Nasri, Piltan, Farzin, Allahdadi, Sadeq, Dialame, Mohammadali, Abbas, Zulkifly

    Published 2011
    “…This research focuses on design Single Input Single Output (SISO) adaptive sliding mode fuzzy PD fuzzy sliding mode algorithm with estimates the equivalent part derived in the Lyapunov sense. …”
    Get full text
    Get full text
    Article
  8. 8
  9. 9
  10. 10
  11. 11

    Upper Limb Joint Angle Estimation Using Wearable IMUs and Personalized Calibration Algorithm by Rahman, Md. Mahmudur, Kok Beng Gan, Kok Beng Gan, Abd Aziz, Noor Azah, Huong, Audrey, Huay Woon You, Huay Woon You

    Published 2023
    “…Multiple trials using the proposed algorithm estimated the elbow joint angle of the rigid body with a maximum RMSE of 0.46◦ . …”
    Get full text
    Get full text
    Get full text
    Article
  12. 12
  13. 13

    Upper Limb Joint Angle Estimation Using Wearable IMUs and Personalized Calibration Algorithm by Md. Mahmudur Rahman, Md. Mahmudur Rahman, Kok Beng Gan, Kok Beng Gan, Abd Aziz, Noor Azah, Audrey Huong, Audrey Huong, Huay Woon You, Huay Woon You

    Published 2023
    “…Multiple trials using the proposed algorithm estimated the elbow joint angle of the rigid body with a maximum RMSE of 0.46◦ Using the IMU manufacturer’s (WitMotion) algorithm (Kalman filter), the maximum RMSE was 1.97◦ . …”
    Get full text
    Get full text
    Get full text
    Article
  14. 14
  15. 15

    MOSELM approach for Voltage Stability Indicator using phasor measurement units by Abidin I.Z., Yap K.S., Saadun N., Abdullah S.K.S., Mohd Sarmin M.K.N.

    Published 2023
    “…Two algorithms were discussed in this paper which looks into estimating voltage stability based upon Thevenin Equivalent values in a system using Voltage and Current Phasors for different loading values. …”
    Conference paper
  16. 16

    Optimal distributed generation and load shedding scheme using artificial bee colony- hill climbing algorithm considering voltage stability and losses indices by Ali Abdallah, Ali Emhemed

    Published 2021
    “…The function of MLSI is to estimate the voltage stability condition and determine sensitive lines in power system. …”
    Get full text
    Get full text
    Thesis
  17. 17

    Integrated attitude determination and control system via magnetic measurements and actuation by Mohammad Abdelrahman, Mohammad Ibraheem, Park, Sang-Young

    Published 2011
    “…Monte-Carlo simulations are used to demonstrate the global asymptotic stability of the controller and the estimator for various initial conditions.…”
    Get full text
    Get full text
    Get full text
    Article
  18. 18
  19. 19
  20. 20

    Optimization of power system stabilizers using participation factor and genetic algorithm by Hassan, L.H., Moghavvemi, M., Almurib, H.A.F., Muttaqi, K.M., Ganapathy, V.G.

    Published 2014
    “…This paper describes a method to determine the optimal location and the number of multi-machine power system stabilizers (PSSs) using participation factor (PF) and genetic algorithm (GA). …”
    Get full text
    Get full text
    Article