Search Results - (( developing line effect algorithm ) OR ( java implication rsa algorithm ))

Refine Results
  1. 1

    Novel techniques for voltage stability assessment and improvement in power system / Ismail Musirin. by Musirin, Ismail

    Published 2004
    “…Few automatic contingency analysis and ranking algorithms due to line and generator outages were separately developed. …”
    Get full text
    Get full text
    Thesis
  2. 2
  3. 3

    Autoreclosure in Extra High Voltage Lines using Taguchi’s Method and Optimized Neural Networks by Desta, Zahlay F., K.S., Ramarao, Taj, Mohammed Baloch

    Published 2008
    “…The algorithms are developed using MATLABTM software. A range of faults are simulated on EHV modeled transmission line using SimPowerSytemsTM, and the spectra of the fault data are analyzed using fast Fourier transform which facilitates extraction of distinct features of each type of fault. …”
    Get full text
    Get full text
    Conference or Workshop Item
  4. 4

    Autoreclosure in Extra High Voltage Lines using Taguchi's Method and Optimized Neural Networks by Desta, Zahlay F., K.S., Rama Rao

    Published 2009
    “…The algorithms are developed using MATLAB software. A range of faults are simulated on EHV modeled transmission line using SimPowerSytems, and the spectra of the fault data are analyzed using fast Fourier transform to extract features of each type of fault. …”
    Get full text
    Get full text
    Conference or Workshop Item
  5. 5

    Review on bio-inspired algorithms approach to solve assembly line balancing problem by Noorazliza, Sulaiman, Junita, Mohamad Saleh, Nor Rokiah Hanum, Md. Haron, Z. A., Kamaruzzaman

    Published 2019
    “…The outcome of this paper shows the effectiveness of bio-inspired algorithms in solving assembly line balancing problem compared to traditional method.…”
    Get full text
    Get full text
    Get full text
    Conference or Workshop Item
  6. 6

    Autoreclosure in extra high voltage lines using taguchi's method and optimized neural networks by K.S.R, Rao, F. D., Zahlay

    Published 2008
    “…The algorithms are developed using MATLABâ„¢ software. A range of faults are simulated on EHV modeled transmission line using SimPowerSytemsâ„¢, and the spectra of the fault data are analyzed using fast Fourier transform which facilitates extraction of distinct features of each type of fault. …”
    Get full text
    Get full text
    Get full text
    Conference or Workshop Item
  7. 7

    Taguchi's method for optimized neural network based autoreclosure in extra high voltage lines by K.S.R., Rao, Z.F., Desta

    Published 2008
    “…For both training and testing purposes, the neural network is fed with the normalized energies of the DC component, the fundamental and the first four harmonics of the faulted voltages. The developed algorithm is verified with dedicated testing data. …”
    Get full text
    Get full text
    Get full text
    Conference or Workshop Item
  8. 8

    Autonomous Positioning Of Unmanned Aerial Vehicle (UAV) For Power Lines Insulator Detection by Sze Sin, Voon, Kho, Lee Chin, Ngu, Sze Song, Annie, Joseph, Kuryati, Kipli

    Published 2024
    “…The machine learning algorithms are utilised to identify and calculate the length of power line insulators. …”
    Get full text
    Get full text
    Get full text
    Article
  9. 9

    Fuzzy Mixed Assembly Line Sequencing and Scheduling Optimization Model Using Multiobjective Dynamic Fuzzy GA by Zahari, Taha, Farzad, Tahriri, Siti Zawiah, Md Dawal

    Published 2014
    “…The simulation results highlight that the performance and efficacy of the proposed novel optimization algorithm are more efficient than the performance of the standard genetic algorithm in mixed assembly line sequencing model.…”
    Get full text
    Get full text
    Get full text
    Article
  10. 10

    Semi-automatic cortical boundary detection / Noor Elaiza Abdul Khalid. by Abdul Khalid, Noor Elaiza

    Published 2010
    “…LPHA proves to be an efficient edge detector evaluation algorithm and FPSO is proven to be an effective edge detection algorithm.…”
    Get full text
    Get full text
    Thesis
  11. 11

    A three-term conjugate gradient method with nonmonotone line search for unconstrained optimization by Moyi, Aliyu Usman, Leong, Wah June

    Published 2016
    “…Numerical experiments carried out on benchmark test problems has clearly indicated the effectiveness of the developed algorithm in terms of efficiency and robustness.…”
    Get full text
    Get full text
    Get full text
    Article
  12. 12

    Optimal distributed generation and load shedding scheme using artificial bee colony- hill climbing algorithm considering voltage stability and losses indices by Ali Abdallah, Ali Emhemed

    Published 2021
    “…The proposed solution is based on the optimization method developed from a combination of the Artificial Bee Colony and Hill Climbing algorithms (ABC-HC) to give the optimal placement and sizing of DG units to be deployed in the system. …”
    Get full text
    Get full text
    Thesis
  13. 13

    Self-Adaptive Autoreclosing Scheme usingI Artificial Neural Network and Taguchi's Methodology in Extra High Voltage Transmission Systems by Desta, Zahlay Fitiwi

    Published 2009
    “…The results show the efficacy of the developed adaptive automatic reclosing scheme. This effectively means it is possible to avoid reclosing before any fault on a transmission line (be it temporary or permanent) is totally cleared.…”
    Get full text
    Get full text
    Thesis
  14. 14

    Avoiding under-reaching in twin circuit lines without residual current input from the parallel line by Mukerjee R.N., Bin Abdullah M.F., Tan K.K., Nallagownden P.

    Published 2023
    “…Also, incorrect sensing of the ground fault due to zero-sequence voltage inversion caused by mutual coupling in the zero-sequence network may lead to false trip of the neighbouring healthy line. The paper develops characteristic expressions for the effective sequence impedances experienced by a twin-circuit, both with and without mutual coupling and presents a non-iterative microprocessor based real time algorithm for computing fault distance and zero sequence compensation in basic distance relaying scheme, Residual current measurement from the parallel circuit is not required in the algorithm. � 2007 RPS.…”
    Conference Paper
  15. 15

    Hybrid intelligent active force controller for robot arms using evolutionary neural networks by Hussein, S. B., Jamaluddin, H., Mailah, M., Zalzala, A. M. S.

    Published 2000
    “…In the first stage, which is performed off-line, the proposed EC algorithm is employed to evolve a pool of ANN structures until they converge to an optimum structure. …”
    Get full text
    Get full text
    Article
  16. 16

    Development of an augmented reality based facility layout planning and optimization / Tan Chee Hau by Tan , Chee Hau

    Published 2020
    “…This research is useful for production line which requires flexibility and agility. The developed AR-based FLP software is fast and effective. …”
    Get full text
    Get full text
    Get full text
    Thesis
  17. 17

    Differential equation fault location algorithm with harmonic effects in power system by Izatti, Md Amin, Mohd Rafi, Adzman, Haziah, Abdul Hamid, Muhd Hafizi, Idris, Melaty, Amirruddin, Omar, Aliman

    Published 2023
    “…In this study, several filters were tested to obtain the lowest fault location error to reduce the effect of harmonic components on the developed fault location algorithm. …”
    Get full text
    Get full text
    Get full text
    Article
  18. 18

    Avoiding under-reaching in twin circuit lines without residual current input from the parallel line by P., Nallagownden, R.N., Mukerjee, M.F., Bin Abdullah, K.K., Tan

    Published 2007
    “…Also, incorrect sensing of the ground fault due to zero-sequence voltage inversion caused by mutual coupling in the zero-sequence network may lead to false trip of the neighbouring healthy line. The paper develops characteristic expressions for the effective sequence impedances experienced by a twin-circuit, both with and without mutual coupling and presents a non-iterative microprocessor based real time algorithm for computing fault distance and zero sequence compensation in basic distance relaying scheme, Residual current measurement from the parallel circuit is not required in the algorithm. …”
    Get full text
    Get full text
    Get full text
    Conference or Workshop Item
  19. 19

    Enhanced hierarchical dynamic bandwidth allocation algorithm with excess bandwidth and SLA techniques for upstream ethernet PON by Sadon S.Kh., Radzi N.A.M., Din N.M., Mustafa I.S., Al-Mansoori M.H., Yaacob M.

    Published 2023
    “…Ethernet PON (EPON) gains the most attention from the researchers as it offers highly flexible and cost effective solution. In this paper we propose two high level scheduler algorithms inside the Optical Line Terminal (OLT) and Optical Network Units (ONU). …”
    Conference paper
  20. 20

    Optimal Reactive Power Dispatch for Voltage Stability Improvement Considering Line Contingencies using PSO by Nor Rul Hasma, Abdullah, I., Musirin

    Published 2013
    “…This paper presents a swarm intelligence algorithm for monitoring and improving voltage stability in power system considering a contingency conditions; line outage. …”
    Get full text
    Get full text
    Conference or Workshop Item