Search Results - (( current implementation level algorithm ) OR ( java simulation optimization algorithm ))
Search alternatives:
- current implementation »
- implementation level »
- level algorithm »
- java simulation »
-
1
Attribute reduction based scheduling algorithm with enhanced hybrid genetic algorithm and particle swarm optimization for optimal device selection
Published 2022“…The simulation is implemented with iFogSim and java programming language. …”
Get full text
Get full text
Article -
2
Enhancement of Ant Colony Optimization for Grid Job Scheduling and Load Balancing
Published 2011“…Global pheromone update is performed after the completion of processing the jobs in order to reduce the pheromone value of resources. A simulation environment was developed using Java programming to test the performance of the proposed EACO algorithm against existing grid resource management algorithms such as Antz algorithm, Particle Swarm Optimization algorithm, Space Shared algorithm and Time Shared algorithm, in terms of processing time and resource utilization. …”
Get full text
Get full text
Get full text
Thesis -
3
Ant colony optimization algorithm for load balancing in grid computing
Published 2012“…The proposed algorithm is known as the enhance ant colony optimization (EACO). …”
Get full text
Get full text
Get full text
Monograph -
4
OPTIMIZED MIN-MIN TASK SCHEDULING ALGORITHM FOR SCIENTIFIC WORKFLOWS IN A CLOUD ENVIRONMENT
Published 2023“…To achieve this, we propose a new noble mechanism called Optimized Min-Min (OMin-Min) algorithm, inspired by the Min-Min algorithm. …”
Review -
5
Embedded system for indoor guidance parking with Dijkstra’s algorithm and ant colony optimization
Published 2019“…This study proposes a car parking management system which applies Dijkstra’s algorithm, Ant Colony Optimization (ACO) and Binary Search Tree (BST) in structuring a guidance system for indoor parking. …”
Get full text
Get full text
Thesis -
6
A simplified synchronous reference frame for indirect current controlled three-level inverter-based shunt active power filters
Published 2016“…However, it suffers from significant delays due to its dependency on a numerical filter and unnecessary computation workloads. Moreover, the algorithm is mostly implemented for the direct current controlled (DCC) based SAPF which operates based on a non-sinusoidal reference current. …”
Get full text
Get full text
Article -
7
Features selection for intrusion detection system using hybridize PSO-SVM
Published 2016“…Hybridize Particle Swarm Optimization (PSO) as a searching algorithm and support vector machine (SVM) as a classifier had been implemented to cope with this problem. …”
Get full text
Get full text
Thesis -
8
Resource management in grid computing using ant colony optimization
Published 2011“…Resources with high pheromone value are selected to process the submitted jobs.Global pheromone update is performed after completion processing the jobs in order to reduce the pheromone value of resources.A simulation environment was developed using Java programming to test the performance of the proposed EACO algorithm against other ant based algorithm, in terms of resource utilization.Experimental results show that EACO produced better grid resource management solution.…”
Get full text
Get full text
Get full text
Get full text
Monograph -
9
Three-phase three-level shunt active power filter with simplified synchronous reference frame
Published 2016“…Shunt active power filter (SAPF) is the most effective solution to current harmonics. In its controller, Synchronous Reference Frame (SRF) principle has widely been applied in current harmonics extraction algorithm due to its simple implementation features. …”
Get full text
Get full text
Conference or Workshop Item -
10
Implementation of locust inspired scheduling algorithm with huge number of servers for energy efficiency in a cloud datacenter
Published 2019“…Cloudsim is used as Discrete Event Simulation tool and Java as coding language to evaluate LACE algorithm. …”
Get full text
Get full text
Thesis -
11
Enhanced Instantaneous Power Theory with average algorithm for indirect current controlled three-level inverter-based shunt active power filter under dynamic state conditions
Published 2016“…An enhanced harmonics extraction algorithm based on Instantaneous Power (PQ) Theory is proposed for indirect current controlled (ICC) three-level neutral point diode clamped (NPC) inverter-based shunt active power filter (SAPF). …”
Get full text
Get full text
Get full text
Article -
12
A refined self-tuning filter-based instantaneous power theory algorithm for indirect current controlled three-level inverter-based shunt active power filter under non-sinusoidal so...
Published 2017“…In this paper, a refined reference current generation algorithm based on instantaneous power (pq) theory is proposed, for operation of an indirect current controlled (ICC) three-level neutral-point diode clamped (NPC) inverter-based shunt active power filter (SAPF) under non-sinusoidal source voltage conditions. …”
Get full text
Get full text
Get full text
Article -
13
A self-tuning filter-based adaptive linear neuron approach for operation of three-level inverter-based shunt active power filters under non-ideal source voltage conditions
Published 2017“…Additionally, the proposed STF-based ADALINE algorithm implements the modified Widrow-Hoff (W-H) weight updating algorithm for fast generation of reference current. …”
Get full text
Get full text
Article -
14
Conjunctions in biological neural architectures for visual pose estimation / Tom´As Maul
Published 2006“…Four levels of analysis are traversed in order of decreasing abstraction: computational, algorithmic, implementational and formational. …”
Get full text
Get full text
Thesis -
15
A modified H-bridge multilevel inverter for photovoltaic system
Published 2010“…MPPT and current control algorithm were implemented in an eZdsp board, TMS320F2812. …”
Get full text
Article -
16
A PI based coordinated maximum power point tracking controller for grid connected photovoltaic system / Md Haidar Islam
Published 2021“…A low complexity grid synchronization controller is implemented to generate parallel and orthogonal components of the grid voltage in a highly computationally efficient manner in order to create a synchronized current reference to the current control loop. …”
Get full text
Get full text
Get full text
Thesis -
17
Five-level inverter with dual reference modulation technique for grid-connected PV system
Published 2010“…A digital PI current control algorithm is implemented in DSP TMS320F2812 to keep the current injected into the grid sinusoidal and to have high dynamic performance with low THD. …”
Get full text
Article -
18
Implementation of Station-To-Station (STS) protocol using Elliptic Curve Digital Signature Al Algorithm / Muhammad Faris Fakhri Rozi, Alya Syuhada Ismail and Emylia Suhaimi
Published 2018“…It was believed that this implementation has increased the level of secrecy in the sharing session using the method applied. …”
Get full text
Get full text
Student Project -
19
SG-PBFS : Shortest Gap-Priority Based Fair Scheduling technique for job scheduling in cloud environment
Published 2024“…To conduct this experiment, we employed the CloudSim simulator, which is implemented using the Java programming language.…”
Get full text
Get full text
Get full text
Get full text
Article -
20
PLL-less SRF technique for operation of SAPF under unbalanced and distorted supply voltage
Published 2018“…Therefore, this paper presents a PLL-less SRF algorithm for generating reference current to effectively control performance of a SAPF developed based on three-level neutral-point-clamped (NPC) inverter. …”
Get full text
Get full text
Conference or Workshop Item
