Non-invasive ultrasonic tomography: liquid/gas flow visualization

This paper presents the non-invasive ultrasonic tomography system for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. The algorithms used to reconstruct the concentration profile for tw...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Rahim, Ruzairi, Fazalul Rahiman, M. H., Mohd. Taib, M. N.
Format: Conference or Workshop Item
Language:en
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/1793/1/ruzairi05_Non-Invasive_Ultrasonic_Tomography.pdf
http://eprints.utm.my/1793/
https://dx.doi.org/10.1109/CCSP.2005.4977199
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1845470544436133888
author Abdul Rahim, Ruzairi
Fazalul Rahiman, M. H.
Mohd. Taib, M. N.
author_facet Abdul Rahim, Ruzairi
Fazalul Rahiman, M. H.
Mohd. Taib, M. N.
author_sort Abdul Rahim, Ruzairi
building UTM Library
collection Institutional Repository
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
continent Asia
country Malaysia
description This paper presents the non-invasive ultrasonic tomography system for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. The algorithms used to reconstruct the concentration profile for two-phase flow using fan-shaped beam scanning geometry were presented. Experiments showed that the performance of the system is acceptable. Results of the experiments using LBPA, HRA and HBRA were discussed.
format Conference or Workshop Item
id my.utm.eprints-1793
institution Universiti Teknologi Malaysia
language en
publishDate 2005
record_format eprints
spelling my.utm.eprints-17932017-08-28T01:38:30Z http://eprints.utm.my/1793/ Non-invasive ultrasonic tomography: liquid/gas flow visualization Abdul Rahim, Ruzairi Fazalul Rahiman, M. H. Mohd. Taib, M. N. TK Electrical engineering. Electronics Nuclear engineering This paper presents the non-invasive ultrasonic tomography system for imaging liquid and gas flow. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous medium. The algorithms used to reconstruct the concentration profile for two-phase flow using fan-shaped beam scanning geometry were presented. Experiments showed that the performance of the system is acceptable. Results of the experiments using LBPA, HRA and HBRA were discussed. 2005-11-14 Conference or Workshop Item NonPeerReviewed application/pdf en http://eprints.utm.my/1793/1/ruzairi05_Non-Invasive_Ultrasonic_Tomography.pdf Abdul Rahim, Ruzairi and Fazalul Rahiman, M. H. and Mohd. Taib, M. N. (2005) Non-invasive ultrasonic tomography: liquid/gas flow visualization. In: Proceeding of 1st Conference on Computers, Communication, and Signal Processing, 14-16 November 2005, Kuala Lumpur. https://dx.doi.org/10.1109/CCSP.2005.4977199
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abdul Rahim, Ruzairi
Fazalul Rahiman, M. H.
Mohd. Taib, M. N.
Non-invasive ultrasonic tomography: liquid/gas flow visualization
title Non-invasive ultrasonic tomography: liquid/gas flow visualization
title_full Non-invasive ultrasonic tomography: liquid/gas flow visualization
title_fullStr Non-invasive ultrasonic tomography: liquid/gas flow visualization
title_full_unstemmed Non-invasive ultrasonic tomography: liquid/gas flow visualization
title_short Non-invasive ultrasonic tomography: liquid/gas flow visualization
title_sort non-invasive ultrasonic tomography: liquid/gas flow visualization
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/1793/1/ruzairi05_Non-Invasive_Ultrasonic_Tomography.pdf
http://eprints.utm.my/1793/
https://dx.doi.org/10.1109/CCSP.2005.4977199
url_provider http://eprints.utm.my/