Minimum separation between lightning protection system and non-integrated metallic structures

Lightning protection; Metals; Roofs; Air-termination systems; constant area criterion; Direct lightning strikes; Electronic systems; Lightning protection systems; Metallic component; Metallic structures; Separation distances; Lightning

Saved in:
Bibliographic Details
Main Authors: Fallah S.N., Gomes C., Izadi M., Kadir M.Z.A.A., Ahmed R.J., Jasni J.B.
Other Authors: 35174161400
Format: Conference Paper
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833350007362682880
author Fallah S.N.
Gomes C.
Izadi M.
Kadir M.Z.A.A.
Ahmed R.J.
Jasni J.B.
author2 35174161400
author_facet 35174161400
Fallah S.N.
Gomes C.
Izadi M.
Kadir M.Z.A.A.
Ahmed R.J.
Jasni J.B.
author_sort Fallah S.N.
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description Lightning protection; Metals; Roofs; Air-termination systems; constant area criterion; Direct lightning strikes; Electronic systems; Lightning protection systems; Metallic component; Metallic structures; Separation distances; Lightning
format Conference Paper
id my.uniten.dspace-23640
institution Universiti Tenaga Nasional
publishDate 2023
publisher Institute of Electrical and Electronics Engineers Inc.
record_format dspace
spelling my.uniten.dspace-236402023-05-29T14:50:41Z Minimum separation between lightning protection system and non-integrated metallic structures Fallah S.N. Gomes C. Izadi M. Kadir M.Z.A.A. Ahmed R.J. Jasni J.B. 35174161400 57201335285 56406980700 25947297000 55832246700 25632671500 Lightning protection; Metals; Roofs; Air-termination systems; constant area criterion; Direct lightning strikes; Electronic systems; Lightning protection systems; Metallic component; Metallic structures; Separation distances; Lightning In the event of a direct lightning strike to a protected building which is integrated with an electrical or electronic system installed on the roof such as roof-top PV system, dangerous arcing may occur between the external lightning protection system (LPS) and the conductive components of the electrical system. To prevent such side flashes, a minimum separation distance between the metallic components and the air termination system is required. Even though, IEC62305-3 Standard provides a formula to specify the necessary separation distance, so far there is no extensive study that has been done to evaluate the suitability of the application of equation to calculate the separation distance, specifically to the safety of electrical systems integrated into the roof top of building. In this study, a new computational method has been developed for calculation of the separation distance between an LPS and metallic components on the roof. In the proposed method which is based on the theoretical background of the IEC62305-3 Standard formula, the break down behavior of the gap geometry between the LPS and the metallic components for the applied voltage across the gap is analyzed. PSCAD software was used to model the LPS and the lightning strokes. � 2018 IEEE. Final 2023-05-29T06:50:40Z 2023-05-29T06:50:40Z 2018 Conference Paper 10.1109/ICLP.2018.8503276 2-s2.0-85056833953 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85056833953&doi=10.1109%2fICLP.2018.8503276&partnerID=40&md5=7807dc7e506bc3a9ce979f060e90c48d https://irepository.uniten.edu.my/handle/123456789/23640 8503276 All Open Access, Green Institute of Electrical and Electronics Engineers Inc. Scopus
spellingShingle Fallah S.N.
Gomes C.
Izadi M.
Kadir M.Z.A.A.
Ahmed R.J.
Jasni J.B.
Minimum separation between lightning protection system and non-integrated metallic structures
title Minimum separation between lightning protection system and non-integrated metallic structures
title_full Minimum separation between lightning protection system and non-integrated metallic structures
title_fullStr Minimum separation between lightning protection system and non-integrated metallic structures
title_full_unstemmed Minimum separation between lightning protection system and non-integrated metallic structures
title_short Minimum separation between lightning protection system and non-integrated metallic structures
title_sort minimum separation between lightning protection system and non-integrated metallic structures
url_provider http://dspace.uniten.edu.my/