Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional

Field study was carried out on the thermal conditions and thermal comfort of occupants in air conditioned buildings in Malaysia. The study was carried out in 10 staff offices and 6 student study areas of Universiti Tenaga Nasional (UNITEN) during October and November 2013, collecting a full set of o...

Full description

Saved in:
Bibliographic Details
Main Authors: Asadi I., Hussein I., Palanisamy K.
Other Authors: 36024950100
Format: Conference Paper
Published: Trans Tech Publications Ltd 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1833412311032791040
author Asadi I.
Hussein I.
Palanisamy K.
author2 36024950100
author_facet 36024950100
Asadi I.
Hussein I.
Palanisamy K.
author_sort Asadi I.
building UNITEN Library
collection Institutional Repository
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
continent Asia
country Malaysia
description Field study was carried out on the thermal conditions and thermal comfort of occupants in air conditioned buildings in Malaysia. The study was carried out in 10 staff offices and 6 student study areas of Universiti Tenaga Nasional (UNITEN) during October and November 2013, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the occupants about the thermal environment at the moment of measurements. The obtained results showed that most places are in acceptable and comfort zone according to Fanger’s predicted mean vote (PMV) model. The neutral air temperature obtained through linear regression analysis of thermal sensation vote (TSV) is 23.9°C for UNITEN. The result of this study demonstrates that the acceptability of thermal comfort among UNITEN occupant is about 78%. © (2014) Trans Tech Publications, Switzerland.
format Conference Paper
id my.uniten.dspace-22010
institution Universiti Tenaga Nasional
publishDate 2023
publisher Trans Tech Publications Ltd
record_format dspace
spelling my.uniten.dspace-220102023-05-16T10:46:39Z Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional Asadi I. Hussein I. Palanisamy K. 36024950100 7006902818 56803626200 Field study was carried out on the thermal conditions and thermal comfort of occupants in air conditioned buildings in Malaysia. The study was carried out in 10 staff offices and 6 student study areas of Universiti Tenaga Nasional (UNITEN) during October and November 2013, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the occupants about the thermal environment at the moment of measurements. The obtained results showed that most places are in acceptable and comfort zone according to Fanger’s predicted mean vote (PMV) model. The neutral air temperature obtained through linear regression analysis of thermal sensation vote (TSV) is 23.9°C for UNITEN. The result of this study demonstrates that the acceptability of thermal comfort among UNITEN occupant is about 78%. © (2014) Trans Tech Publications, Switzerland. Final 2023-05-16T02:46:39Z 2023-05-16T02:46:39Z 2014 Conference Paper 10.4028/www.scientific.net/AMM.672-674.1665 2-s2.0-84920904074 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84920904074&doi=10.4028%2fwww.scientific.net%2fAMM.672-674.1665&partnerID=40&md5=e6950f6aca2891d4d3e716caac0021c6 https://irepository.uniten.edu.my/handle/123456789/22010 672-674 1665 1669 Trans Tech Publications Ltd Scopus
spellingShingle Asadi I.
Hussein I.
Palanisamy K.
Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional
title Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional
title_full Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional
title_fullStr Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional
title_full_unstemmed Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional
title_short Analysis on thermal comfort of air-conditioned buildings in Malaysia: Case study of universiti tenaga nasional
title_sort analysis on thermal comfort of air-conditioned buildings in malaysia: case study of universiti tenaga nasional
url_provider http://dspace.uniten.edu.my/