Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification"
The first phase of this paper is aimed to develop a standard test procedure for short-duration hypersonic test facility that build at the Universiti Tenaga Nasional “UNITEN” in Malaysia. The facility has been designed, built, and commissioned for different values of diaphragm pressure ratios. A theo...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Book Section |
| Published: |
ASME
2006
|
| Subjects: | |
| Online Access: | http://eprints.intimal.edu.my/1184/ http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=1593320 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1831337330210766848 |
|---|---|
| author | Amir, Al-Falahi Yusaf, T. Yusoff, M. Z. |
| author_facet | Amir, Al-Falahi Yusaf, T. Yusoff, M. Z. |
| author_sort | Amir, Al-Falahi |
| building | INTI Library |
| collection | Institutional Repository |
| content_provider | INTI International University |
| content_source | INTI Institutional Repository |
| continent | Asia |
| country | Malaysia |
| description | The first phase of this paper is aimed to develop a standard test procedure for short-duration hypersonic test facility that build at the Universiti Tenaga Nasional “UNITEN” in Malaysia. The facility has been designed, built, and commissioned for different values of diaphragm pressure ratios. A theoretical model was developed to evaluate the Mach number values as a function of diaphragm pressure ratio for different working fluids. The second phase is to run experimental tests for different operating conditions. The calculated parameters which are pressure, temperature and velocity were very comparable to the practical results. A high precision in house made thermocouple was used to measure the temperature profile during the facility operation. A numerical transient heat transfer mathematical model was developed to evaluate the heat flux from the surface temperature history. The principle of operation and the reasoning behind building such a facility are explained, and the governing equations for the shock tube are presented. |
| format | Book Section |
| id | my-inti-eprints.1184 |
| institution | INTI International University |
| publishDate | 2006 |
| publisher | ASME |
| record_format | eprints |
| spelling | my-inti-eprints.11842018-10-18T10:14:01Z http://eprints.intimal.edu.my/1184/ Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification" Amir, Al-Falahi Yusaf, T. Yusoff, M. Z. T Technology (General) TA Engineering (General). Civil engineering (General) The first phase of this paper is aimed to develop a standard test procedure for short-duration hypersonic test facility that build at the Universiti Tenaga Nasional “UNITEN” in Malaysia. The facility has been designed, built, and commissioned for different values of diaphragm pressure ratios. A theoretical model was developed to evaluate the Mach number values as a function of diaphragm pressure ratio for different working fluids. The second phase is to run experimental tests for different operating conditions. The calculated parameters which are pressure, temperature and velocity were very comparable to the practical results. A high precision in house made thermocouple was used to measure the temperature profile during the facility operation. A numerical transient heat transfer mathematical model was developed to evaluate the heat flux from the surface temperature history. The principle of operation and the reasoning behind building such a facility are explained, and the governing equations for the shock tube are presented. ASME 2006 Book Section PeerReviewed Amir, Al-Falahi and Yusaf, T. and Yusoff, M. Z. (2006) Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification". In: ASME 8th Biennial Conference on Engineering Systems Design and Analysis. ASME, pp. 541-549. ISBN 0-7918-4248-7 http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=1593320 doi:10.1115/ESDA2006-95448 |
| spellingShingle | T Technology (General) TA Engineering (General). Civil engineering (General) Amir, Al-Falahi Yusaf, T. Yusoff, M. Z. Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification" |
| title | Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification" |
| title_full | Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification" |
| title_fullStr | Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification" |
| title_full_unstemmed | Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification" |
| title_short | Universiti Tenaga Nasional short duration hypersonic test faciliy "calibration and verification" |
| title_sort | universiti tenaga nasional short duration hypersonic test faciliy "calibration and verification" |
| topic | T Technology (General) TA Engineering (General). Civil engineering (General) |
| url | http://eprints.intimal.edu.my/1184/ http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=1593320 |
| url_provider | http://eprints.intimal.edu.my |