A comparison between static load test and high strain dynamic test on bored piles

Piles are both statically and dynamically tested to obtain the capacity and to verify design. Both the test will provide results that may vary base on the method applied in conducting the test. It is therefore, necessary to compare the results of a static load test with dynamic load test. Many compa...

Full description

Saved in:
Bibliographic Details
Main Author: Murugun @ Arokiasamy, Michael Angelo
Format: Thesis
Language:English
Published: 2006
Subjects:
Online Access:http://eprints.utm.my/id/eprint/2329/1/MichaelAngeloMFKA2006.pdf
http://eprints.utm.my/id/eprint/2329/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.2329
record_format eprints
spelling my.utm.23292018-06-25T00:40:39Z http://eprints.utm.my/id/eprint/2329/ A comparison between static load test and high strain dynamic test on bored piles Murugun @ Arokiasamy, Michael Angelo TA Engineering (General). Civil engineering (General) Piles are both statically and dynamically tested to obtain the capacity and to verify design. Both the test will provide results that may vary base on the method applied in conducting the test. It is therefore, necessary to compare the results of a static load test with dynamic load test. Many comparison studies are conducted worldwide, but most of it is for displacement pile. Therefore, the results of the test are compared for replacement piles. The piles are tested statically prior to dynamic test. The test results shows that a good agreement have achieved between both the test with plus minus 2mm at working load in terms of settlement. Comparatively the settlement predicted in dynamic load test is smaller compared to static load test. In terms of total capacity, the Davisson’s method gives the lowest value compared to other methods. The Davisson’s method is used to compare the results because it is more conservative. The comparison shows that the piles are within 20% relative to the capacity obtained through Davisson’s method. Since the static test was conducted prior to dynamic test, the capacity obtained from dynamic test is higher due to the pile undergone elastic compression during static load test and also due to soil setup. The shaft distribution show that large shaft distribution obtained on long piles. They are comparable with the dynamic test taking into account the time factor 2006-05 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/2329/1/MichaelAngeloMFKA2006.pdf Murugun @ Arokiasamy, Michael Angelo (2006) A comparison between static load test and high strain dynamic test on bored piles. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Murugun @ Arokiasamy, Michael Angelo
A comparison between static load test and high strain dynamic test on bored piles
description Piles are both statically and dynamically tested to obtain the capacity and to verify design. Both the test will provide results that may vary base on the method applied in conducting the test. It is therefore, necessary to compare the results of a static load test with dynamic load test. Many comparison studies are conducted worldwide, but most of it is for displacement pile. Therefore, the results of the test are compared for replacement piles. The piles are tested statically prior to dynamic test. The test results shows that a good agreement have achieved between both the test with plus minus 2mm at working load in terms of settlement. Comparatively the settlement predicted in dynamic load test is smaller compared to static load test. In terms of total capacity, the Davisson’s method gives the lowest value compared to other methods. The Davisson’s method is used to compare the results because it is more conservative. The comparison shows that the piles are within 20% relative to the capacity obtained through Davisson’s method. Since the static test was conducted prior to dynamic test, the capacity obtained from dynamic test is higher due to the pile undergone elastic compression during static load test and also due to soil setup. The shaft distribution show that large shaft distribution obtained on long piles. They are comparable with the dynamic test taking into account the time factor
format Thesis
author Murugun @ Arokiasamy, Michael Angelo
author_facet Murugun @ Arokiasamy, Michael Angelo
author_sort Murugun @ Arokiasamy, Michael Angelo
title A comparison between static load test and high strain dynamic test on bored piles
title_short A comparison between static load test and high strain dynamic test on bored piles
title_full A comparison between static load test and high strain dynamic test on bored piles
title_fullStr A comparison between static load test and high strain dynamic test on bored piles
title_full_unstemmed A comparison between static load test and high strain dynamic test on bored piles
title_sort comparison between static load test and high strain dynamic test on bored piles
publishDate 2006
url http://eprints.utm.my/id/eprint/2329/1/MichaelAngeloMFKA2006.pdf
http://eprints.utm.my/id/eprint/2329/
_version_ 1643643562222419968
score 13.145126