Photon-induced positron annihilation for standoff bomb detection

We describe an approach to detect improvised explosive devices (IEDs) by using photon-induced positron annihilation radiation (PIPAR). This system relies on back-scattered ? photons from the target and surrounding objects following exposure to high energy X-rays from a betatron. In this work we simu...

Full description

Saved in:
Bibliographic Details
Main Authors: Bradley, D. A., Hashim, S., Cabello, J., Wells, K., Dunn, W. L.
Format: Article
Published: Elsevier 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/13725/
http://dx.doi.org/10.1016/j.nima.2009.10.073
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.13725
record_format eprints
spelling my.utm.137252011-08-12T02:10:41Z http://eprints.utm.my/id/eprint/13725/ Photon-induced positron annihilation for standoff bomb detection Bradley, D. A. Hashim, S. Cabello, J. Wells, K. Dunn, W. L. QC Physics We describe an approach to detect improvised explosive devices (IEDs) by using photon-induced positron annihilation radiation (PIPAR). This system relies on back-scattered ? photons from the target and surrounding objects following exposure to high energy X-rays from a betatron. In this work we simulate the use of Bremsstrahlung source operating at 3.5 MeV, with a scintillation detector, working in PIPAR mode, in order to reduce noise produced by undesired back-scattering from the surrounding objects. In this paper, we describe the basic imaging method and preliminary results on simulating a suitable betatron source. Two types of X-ray filters copper (Cu) and aluminium (Al), have been used in the simulation to observe their differences in the deposited energy spectrum in the iron target. It was found that the use of iron target in conjunction with 2 mm Al filter is capable of detecting annihilation ? photons. An initiated experiment with an interlaced source also shows promise. Elsevier 2010 Article PeerReviewed Bradley, D. A. and Hashim, S. and Cabello, J. and Wells, K. and Dunn, W. L. (2010) Photon-induced positron annihilation for standoff bomb detection. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 619 (1-3). pp. 415-418. ISSN 01689002 http://dx.doi.org/10.1016/j.nima.2009.10.073 doi:10.1016/j.nima.2009.10.073
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QC Physics
spellingShingle QC Physics
Bradley, D. A.
Hashim, S.
Cabello, J.
Wells, K.
Dunn, W. L.
Photon-induced positron annihilation for standoff bomb detection
description We describe an approach to detect improvised explosive devices (IEDs) by using photon-induced positron annihilation radiation (PIPAR). This system relies on back-scattered ? photons from the target and surrounding objects following exposure to high energy X-rays from a betatron. In this work we simulate the use of Bremsstrahlung source operating at 3.5 MeV, with a scintillation detector, working in PIPAR mode, in order to reduce noise produced by undesired back-scattering from the surrounding objects. In this paper, we describe the basic imaging method and preliminary results on simulating a suitable betatron source. Two types of X-ray filters copper (Cu) and aluminium (Al), have been used in the simulation to observe their differences in the deposited energy spectrum in the iron target. It was found that the use of iron target in conjunction with 2 mm Al filter is capable of detecting annihilation ? photons. An initiated experiment with an interlaced source also shows promise.
format Article
author Bradley, D. A.
Hashim, S.
Cabello, J.
Wells, K.
Dunn, W. L.
author_facet Bradley, D. A.
Hashim, S.
Cabello, J.
Wells, K.
Dunn, W. L.
author_sort Bradley, D. A.
title Photon-induced positron annihilation for standoff bomb detection
title_short Photon-induced positron annihilation for standoff bomb detection
title_full Photon-induced positron annihilation for standoff bomb detection
title_fullStr Photon-induced positron annihilation for standoff bomb detection
title_full_unstemmed Photon-induced positron annihilation for standoff bomb detection
title_sort photon-induced positron annihilation for standoff bomb detection
publisher Elsevier
publishDate 2010
url http://eprints.utm.my/id/eprint/13725/
http://dx.doi.org/10.1016/j.nima.2009.10.073
_version_ 1643646261410136064
score 13.1944895