Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients
Insulin infusion therapy implementing a sliding scale is mainly used in Malaysia's ICU to control blood glucose (BG) levels. However, the sliding scale is a one-size-fits-All protocol, which may cause hypoglycemia events when trying to control hyperglycemia among ICU patients. Hence, this study...
Saved in:
Main Authors: | , , , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2024
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-34347 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-343472024-10-14T11:19:12Z Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients Zukhi J. Suhaimi F.M. Mazlan M.Z. Muhammad F. Sopian M.M. Jamaludin U.K. Razak N. 57194705279 36247893200 57192209115 59207055100 57202639393 55330889600 37059587300 diabetes mellitus FiO<sub>2</sub> insulin infusion therapy insulin sensitivity MAP Blood Blood pressure Glucose Patient treatment Blood glucose Clinical protocols Diabetes mellitus FiO2 Hyperglycaemia Hypoglycaemia Insulin infusion therapy Insulin infusions Insulin sensitivity Mean arterial pressure Insulin Insulin infusion therapy implementing a sliding scale is mainly used in Malaysia's ICU to control blood glucose (BG) levels. However, the sliding scale is a one-size-fits-All protocol, which may cause hypoglycemia events when trying to control hyperglycemia among ICU patients. Hence, this study evaluates two newly developed protocols with potential variables of insulin sensitivity (SI), a fraction of inspired oxygen (FiO 2), and mean arterial pressure (MAP) to improve current insulin infusion therapy with personalized protocols and reduce the hypoglycemia event. Eighty-one diabetes mellitus patients who stayed in the ICU and received insulin infusion therapy were selected for this study. Two new protocols were developed, and the BG target was to be controlled within 8.0-10.0 mmol/L. Protocol A includes BG and SI, while Protocol B includes BG, SI, FiO2, and MAP. The outcomes from these protocols were compared with the performance of the clinical protocol. Protocol A resulted in 0.01 % of severe hypoglycemia events (BG < 2.2 mmol/L). Additionally, protocol A reduced severe hypoglycemia by 0.03% compared to the current protocol. Meanwhile, Protocol B had a similar percentage measurement of severe hypoglycemia events to the clinical protocol (0.04 %). Both protocols were able to control the blood glucose level within the target range with higher percentages of 28.45% and 28.22%, respectively, compared to the current clinical protocol (25.30%). Nevertheless, Protocol A and Protocol B had hyperglycemia events (BG > 10.0 mmol/L) slightly higher than clinical protocol, with percentage differences of 1.13% and 2.85%, respectively. This is because the insulin rate applied in both protocols was lower than the clinical protocol. The median insulin rate for Protocol A and Protocol B was the same, which was 1.2 U/hr, while the clinical protocol was 1.5 U/hr. The BG outcomes including median BG per-patient, percentage of severe hypoglycemia, hypoglycemia, hyperglycemia, and the BG within the target range, from Protocol A and Protocol B were not significantly different from the clinical protocol, with a p-value > 0.05. The potential variables introduced in the new protocols are able to reduce severe hypoglycemia events. However, they could not reduce the hyperglycemia events as both protocols provided lower insulin doses than the clinical protocol. Developing a personalized protocol is crucial, and more trials with large numbers of subjects are needed to properly design tight glycemic control for managing BG levels. � 2023 IEEE. Final 2024-10-14T03:19:12Z 2024-10-14T03:19:12Z 2023 Conference Paper 10.1109/ICHST59286.2023.10565326 2-s2.0-85197663695 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85197663695&doi=10.1109%2fICHST59286.2023.10565326&partnerID=40&md5=35dcc848ff0c073a6ad3956d80a3a3e0 https://irepository.uniten.edu.my/handle/123456789/34347 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
diabetes mellitus FiO<sub>2</sub> insulin infusion therapy insulin sensitivity MAP Blood Blood pressure Glucose Patient treatment Blood glucose Clinical protocols Diabetes mellitus FiO2 Hyperglycaemia Hypoglycaemia Insulin infusion therapy Insulin infusions Insulin sensitivity Mean arterial pressure Insulin |
spellingShingle |
diabetes mellitus FiO<sub>2</sub> insulin infusion therapy insulin sensitivity MAP Blood Blood pressure Glucose Patient treatment Blood glucose Clinical protocols Diabetes mellitus FiO2 Hyperglycaemia Hypoglycaemia Insulin infusion therapy Insulin infusions Insulin sensitivity Mean arterial pressure Insulin Zukhi J. Suhaimi F.M. Mazlan M.Z. Muhammad F. Sopian M.M. Jamaludin U.K. Razak N. Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients |
description |
Insulin infusion therapy implementing a sliding scale is mainly used in Malaysia's ICU to control blood glucose (BG) levels. However, the sliding scale is a one-size-fits-All protocol, which may cause hypoglycemia events when trying to control hyperglycemia among ICU patients. Hence, this study evaluates two newly developed protocols with potential variables of insulin sensitivity (SI), a fraction of inspired oxygen (FiO 2), and mean arterial pressure (MAP) to improve current insulin infusion therapy with personalized protocols and reduce the hypoglycemia event. Eighty-one diabetes mellitus patients who stayed in the ICU and received insulin infusion therapy were selected for this study. Two new protocols were developed, and the BG target was to be controlled within 8.0-10.0 mmol/L. Protocol A includes BG and SI, while Protocol B includes BG, SI, FiO2, and MAP. The outcomes from these protocols were compared with the performance of the clinical protocol. Protocol A resulted in 0.01 % of severe hypoglycemia events (BG < 2.2 mmol/L). Additionally, protocol A reduced severe hypoglycemia by 0.03% compared to the current protocol. Meanwhile, Protocol B had a similar percentage measurement of severe hypoglycemia events to the clinical protocol (0.04 %). Both protocols were able to control the blood glucose level within the target range with higher percentages of 28.45% and 28.22%, respectively, compared to the current clinical protocol (25.30%). Nevertheless, Protocol A and Protocol B had hyperglycemia events (BG > 10.0 mmol/L) slightly higher than clinical protocol, with percentage differences of 1.13% and 2.85%, respectively. This is because the insulin rate applied in both protocols was lower than the clinical protocol. The median insulin rate for Protocol A and Protocol B was the same, which was 1.2 U/hr, while the clinical protocol was 1.5 U/hr. The BG outcomes including median BG per-patient, percentage of severe hypoglycemia, hypoglycemia, hyperglycemia, and the BG within the target range, from Protocol A and Protocol B were not significantly different from the clinical protocol, with a p-value > 0.05. The potential variables introduced in the new protocols are able to reduce severe hypoglycemia events. However, they could not reduce the hyperglycemia events as both protocols provided lower insulin doses than the clinical protocol. Developing a personalized protocol is crucial, and more trials with large numbers of subjects are needed to properly design tight glycemic control for managing BG levels. � 2023 IEEE. |
author2 |
57194705279 |
author_facet |
57194705279 Zukhi J. Suhaimi F.M. Mazlan M.Z. Muhammad F. Sopian M.M. Jamaludin U.K. Razak N. |
format |
Conference Paper |
author |
Zukhi J. Suhaimi F.M. Mazlan M.Z. Muhammad F. Sopian M.M. Jamaludin U.K. Razak N. |
author_sort |
Zukhi J. |
title |
Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients |
title_short |
Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients |
title_full |
Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients |
title_fullStr |
Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients |
title_full_unstemmed |
Evaluation of New Insulin Infusion Therapy with Potential Variables for Diabetes Mellitus ICU Patients |
title_sort |
evaluation of new insulin infusion therapy with potential variables for diabetes mellitus icu patients |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2024 |
_version_ |
1814061051428208640 |
score |
13.214268 |