Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB)
Proceedings of the 9th International Conference on the Properties and Applications of Dielectric Materials (ICPADM) 2009 at Harbin, China on 19 July 2009 through 23 July 2009. Link to publisher's homepage at http://ezproxy.unimap.edu.my:2080/Xplore/dynhome.jsp?tag=1
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Working Paper |
Language: | English |
Published: |
AIP Publishing
2014
|
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/dspace/handle/123456789/35188 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.unimap-35188 |
---|---|
record_format |
dspace |
spelling |
my.unimap-351882014-06-08T07:00:27Z Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB) Solin, I. K. Yolanda, O. Rakhmad Arief, Siregar, Dr. irvan@pln-jawa-bali.co.id otty@pln-jawa-bali.co.id rakhmad@unimap.edu.my Partial discharge Sensor Vibration Proceedings of the 9th International Conference on the Properties and Applications of Dielectric Materials (ICPADM) 2009 at Harbin, China on 19 July 2009 through 23 July 2009. Link to publisher's homepage at http://ezproxy.unimap.edu.my:2080/Xplore/dynhome.jsp?tag=1 This paper is a study and share information of partial discharge measurement and vibration monitoring on power transformer. Power transformer is one of the critical components in power plant and transmission power system. Therefore, an appropriate maintenance program should be applied to the transformer in order to make power system more reliable and to prevent transformer failure at early stage. One of the problems concerning the power transformer is high level noise during its operation. 2014-06-08T07:00:27Z 2014-06-08T07:00:27Z 2009-07 Working Paper p. 521-524 978-1-4244-4367-3 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5252377 http://dspace.unimap.edu.my:80/dspace/handle/123456789/35188 http://dx.doi.org/10.1109/ICPADM.2009.5252377 en Proceeding of the 9th International Conference on the Properties and Applications of Dielectric Materials (ICPADM 2009); AIP Publishing |
institution |
Universiti Malaysia Perlis |
building |
UniMAP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Perlis |
content_source |
UniMAP Library Digital Repository |
url_provider |
http://dspace.unimap.edu.my/ |
language |
English |
topic |
Partial discharge Sensor Vibration |
spellingShingle |
Partial discharge Sensor Vibration Solin, I. K. Yolanda, O. Rakhmad Arief, Siregar, Dr. Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB) |
description |
Proceedings of the 9th International Conference on the Properties and Applications of Dielectric Materials (ICPADM) 2009 at Harbin, China on 19 July 2009 through 23 July 2009. Link to publisher's homepage at http://ezproxy.unimap.edu.my:2080/Xplore/dynhome.jsp?tag=1 |
author2 |
irvan@pln-jawa-bali.co.id |
author_facet |
irvan@pln-jawa-bali.co.id Solin, I. K. Yolanda, O. Rakhmad Arief, Siregar, Dr. |
format |
Working Paper |
author |
Solin, I. K. Yolanda, O. Rakhmad Arief, Siregar, Dr. |
author_sort |
Solin, I. K. |
title |
Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB) |
title_short |
Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB) |
title_full |
Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB) |
title_fullStr |
Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB) |
title_full_unstemmed |
Partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 dB) |
title_sort |
partial discharge measurement and vibration monitoring on power transformer case study on power transformer with high level noise (75.22 db) |
publisher |
AIP Publishing |
publishDate |
2014 |
url |
http://dspace.unimap.edu.my:80/dspace/handle/123456789/35188 |
_version_ |
1643797748064976896 |
score |
13.214268 |