Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease

Early detection of chronic kidney disease is important to prevent progression of irreversible kidney damage, reducing the need for renal transplantation. Shear wave elastography is ideal as a quantitative imaging modality to detect chronic kidney disease because of its non-invasive nature, low cost...

Full description

Saved in:
Bibliographic Details
Main Authors: Lim, William T. H., Ooi, Ean H., Foo, Ji J., Ng, Kwan Hoong, Wong, Jeannie Hsiu Ding, Leong, Sook S.
Format: Article
Published: Elsevier Science Inc 2021
Subjects:
Online Access:http://eprints.um.edu.my/28493/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.28493
record_format eprints
spelling my.um.eprints.284932022-08-15T01:50:40Z http://eprints.um.edu.my/28493/ Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease Lim, William T. H. Ooi, Ean H. Foo, Ji J. Ng, Kwan Hoong Wong, Jeannie Hsiu Ding Leong, Sook S. R Medicine (General) Early detection of chronic kidney disease is important to prevent progression of irreversible kidney damage, reducing the need for renal transplantation. Shear wave elastography is ideal as a quantitative imaging modality to detect chronic kidney disease because of its non-invasive nature, low cost and portability, making it highly accessible. However, the complexity of the kidney architecture and its tissue properties give rise to various confounding factors that affect the reliability of shear wave elastography in detecting chronic kidney disease, thus limiting its application to clinical trials. The objective of this review is to highlight the confounding factors presented by the complex properties of the kidney, in addition to outlining potential mitigation strategies, along with the prospect of increasing the versatility and reliability of shear wave elastography in detecting chronic kidney disease. (C) 2021 World Federation for Ultrasound in Medicine & Biology. All rights reserved. Elsevier Science Inc 2021-08 Article PeerReviewed Lim, William T. H. and Ooi, Ean H. and Foo, Ji J. and Ng, Kwan Hoong and Wong, Jeannie Hsiu Ding and Leong, Sook S. (2021) Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease. Ultrasound in Medicine and Biology, 47 (8). pp. 2033-2047. ISSN 0301-5629, DOI https://doi.org/10.1016/j.ultrasmedbio.2021.03.030 <https://doi.org/10.1016/j.ultrasmedbio.2021.03.030>. 10.1016/j.ultrasmedbio.2021.03.030
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine (General)
spellingShingle R Medicine (General)
Lim, William T. H.
Ooi, Ean H.
Foo, Ji J.
Ng, Kwan Hoong
Wong, Jeannie Hsiu Ding
Leong, Sook S.
Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease
description Early detection of chronic kidney disease is important to prevent progression of irreversible kidney damage, reducing the need for renal transplantation. Shear wave elastography is ideal as a quantitative imaging modality to detect chronic kidney disease because of its non-invasive nature, low cost and portability, making it highly accessible. However, the complexity of the kidney architecture and its tissue properties give rise to various confounding factors that affect the reliability of shear wave elastography in detecting chronic kidney disease, thus limiting its application to clinical trials. The objective of this review is to highlight the confounding factors presented by the complex properties of the kidney, in addition to outlining potential mitigation strategies, along with the prospect of increasing the versatility and reliability of shear wave elastography in detecting chronic kidney disease. (C) 2021 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
format Article
author Lim, William T. H.
Ooi, Ean H.
Foo, Ji J.
Ng, Kwan Hoong
Wong, Jeannie Hsiu Ding
Leong, Sook S.
author_facet Lim, William T. H.
Ooi, Ean H.
Foo, Ji J.
Ng, Kwan Hoong
Wong, Jeannie Hsiu Ding
Leong, Sook S.
author_sort Lim, William T. H.
title Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease
title_short Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease
title_full Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease
title_fullStr Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease
title_full_unstemmed Shear wave elastography: A review on the confounding factors and their potential mitigation in detecting chronic kidney disease
title_sort shear wave elastography: a review on the confounding factors and their potential mitigation in detecting chronic kidney disease
publisher Elsevier Science Inc
publishDate 2021
url http://eprints.um.edu.my/28493/
_version_ 1744649119321817088
score 13.1944895