Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot

This paper described a failure investigation of 13,200 gallons GFRP water storage tank that had happened at Institut Kemahiran Belia Negara (IKBN) Jitra, Kedah. Based on the preliminary observation, the failure started at the outlet flange hole where the water propagated inside the tank's wall...

Full description

Saved in:
Bibliographic Details
Main Authors: Mat Rejab, Mohd Ruzaimi, Abu Hasan, Shukur, Mahbot, Hasnulfikri
Format: Conference or Workshop Item
Language:English
Published: 2006
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/81919/1/81919.PDF
https://ir.uitm.edu.my/id/eprint/81919/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.81919
record_format eprints
spelling my.uitm.ir.819192023-11-16T23:39:30Z https://ir.uitm.edu.my/id/eprint/81919/ Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot Mat Rejab, Mohd Ruzaimi Abu Hasan, Shukur Mahbot, Hasnulfikri Manufacturing industries This paper described a failure investigation of 13,200 gallons GFRP water storage tank that had happened at Institut Kemahiran Belia Negara (IKBN) Jitra, Kedah. Based on the preliminary observation, the failure started at the outlet flange hole where the water propagated inside the tank's wall and cracking the laminated composites. Four standard tests have been performed to investigate either the GFRP material or other factors that caused the tank to burst. Then, comparisons have been made with SIRIM's standard testing on fabricating water storage tanks and the results show that the material passed the minimum requirements of the tests. At the end of the investigation, the major failure that had been concluded was that lite fabricator is not using a good 'hand-lay up' technique to manufacture GFR? water storage tank according to the design specifications. These investigation results will bring advantageous to the researchers and water tank fabricalors in seeking the proper fabrication of GFRP water storage tanks with high mechanical performance, very robust and safe to be used in the residential areas. 2006 Conference or Workshop Item PeerReviewed text en https://ir.uitm.edu.my/id/eprint/81919/1/81919.PDF Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot. (2006) In: Volume No. 1: Science and Technology, 30 – 31 May 2006, Swiss Garden Resort & Spa Kuantan, Pahang.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Manufacturing industries
spellingShingle Manufacturing industries
Mat Rejab, Mohd Ruzaimi
Abu Hasan, Shukur
Mahbot, Hasnulfikri
Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot
description This paper described a failure investigation of 13,200 gallons GFRP water storage tank that had happened at Institut Kemahiran Belia Negara (IKBN) Jitra, Kedah. Based on the preliminary observation, the failure started at the outlet flange hole where the water propagated inside the tank's wall and cracking the laminated composites. Four standard tests have been performed to investigate either the GFRP material or other factors that caused the tank to burst. Then, comparisons have been made with SIRIM's standard testing on fabricating water storage tanks and the results show that the material passed the minimum requirements of the tests. At the end of the investigation, the major failure that had been concluded was that lite fabricator is not using a good 'hand-lay up' technique to manufacture GFR? water storage tank according to the design specifications. These investigation results will bring advantageous to the researchers and water tank fabricalors in seeking the proper fabrication of GFRP water storage tanks with high mechanical performance, very robust and safe to be used in the residential areas.
format Conference or Workshop Item
author Mat Rejab, Mohd Ruzaimi
Abu Hasan, Shukur
Mahbot, Hasnulfikri
author_facet Mat Rejab, Mohd Ruzaimi
Abu Hasan, Shukur
Mahbot, Hasnulfikri
author_sort Mat Rejab, Mohd Ruzaimi
title Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot
title_short Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot
title_full Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot
title_fullStr Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot
title_full_unstemmed Failure investigation of gfrp water storage tank: a case study at IKBN Jitra, Kedah / Mohd Ruzaimi Mat Rejab, Shukur Abu Hasan and Hasnulfikri Mahbot
title_sort failure investigation of gfrp water storage tank: a case study at ikbn jitra, kedah / mohd ruzaimi mat rejab, shukur abu hasan and hasnulfikri mahbot
publishDate 2006
url https://ir.uitm.edu.my/id/eprint/81919/1/81919.PDF
https://ir.uitm.edu.my/id/eprint/81919/
_version_ 1783882200385585152
score 13.197875