A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria
This project aims to design a low cost and portable heart and respiratory rate monitoring system. The proposed monitoring system was combining both the heart and respiratory rate in one system. The heart rate monitoring system was using an infrared LED and photodiode for the pulse sensor while the r...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/105774/1/105774.pdf https://ir.uitm.edu.my/id/eprint/105774/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.105774 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.1057742024-11-30T23:23:23Z https://ir.uitm.edu.my/id/eprint/105774/ A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria Zakaria, Mohd Hilmi Firdaus Cardiac dynamics. Including beat, rate, output, acceleration, rhythm This project aims to design a low cost and portable heart and respiratory rate monitoring system. The proposed monitoring system was combining both the heart and respiratory rate in one system. The heart rate monitoring system was using an infrared LED and photodiode for the pulse sensor while the respiratory rate monitoring system was using a thermistor as a sensor. The system has been tested for a group of students with an age between 20 to 25 years old for the functionality test. The data were recorded and has been compared with the standard heart and respiratory rate measurement for the same group age. Both heart and respiratory rate shows a normal measurement where the heart rate result was between 60 to 100 beats per minute (BPM) and the the respiratory rate result was between 12 to 18 breaths per minute (BPM). It shows that this proposed system are able to produce a reliable measurement data for both heart and respiratory rate monitoring system. 2014 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/105774/1/105774.pdf A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria. (2014) pp. 1-5. |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Cardiac dynamics. Including beat, rate, output, acceleration, rhythm |
spellingShingle |
Cardiac dynamics. Including beat, rate, output, acceleration, rhythm Zakaria, Mohd Hilmi Firdaus A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria |
description |
This project aims to design a low cost and portable heart and respiratory rate monitoring system. The proposed monitoring system was combining both the heart and respiratory rate in one system. The heart rate monitoring system was using an infrared LED and photodiode for the pulse sensor while the respiratory rate monitoring system was using a thermistor as a sensor. The system has been tested for a group of students with an age between 20 to 25 years old for the functionality test. The data were recorded and has been compared with the standard heart and respiratory rate measurement for the same group age. Both heart and respiratory rate shows a normal measurement where the heart rate result was between 60 to 100 beats per minute (BPM) and the the respiratory rate result was between 12 to 18 breaths per minute (BPM). It shows that this proposed system are able to produce a reliable measurement data for both heart and respiratory rate monitoring system. |
format |
Article |
author |
Zakaria, Mohd Hilmi Firdaus |
author_facet |
Zakaria, Mohd Hilmi Firdaus |
author_sort |
Zakaria, Mohd Hilmi Firdaus |
title |
A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria |
title_short |
A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria |
title_full |
A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria |
title_fullStr |
A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria |
title_full_unstemmed |
A low cost digital heart and respiratory rate monitoring system: article / Mohd Hilmi Firdaus Zakaria |
title_sort |
low cost digital heart and respiratory rate monitoring system: article / mohd hilmi firdaus zakaria |
publishDate |
2014 |
url |
https://ir.uitm.edu.my/id/eprint/105774/1/105774.pdf https://ir.uitm.edu.my/id/eprint/105774/ |
_version_ |
1817847331759849472 |
score |
13.222552 |