Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction

The presence of pharmaceuticals in the environment had become a cause for snowballing concern in recent years. A wide range of pharmaceuticals had been discovered in fresh and marine waters and it had recently been shown that even in small quantities these compounds have the...

Full description

Saved in:
Bibliographic Details
Main Authors: Helal Uddin, A.B.M., Alaama, Mohammed, Kamarbashrudin, Siti Khadijah Rose, Izat, I'zma
Format: Conference or Workshop Item
Language:English
Published: 2016
Subjects:
Online Access:http://irep.iium.edu.my/55470/1/PRC-2016.pdf
http://irep.iium.edu.my/55470/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.iium.irep.55470
record_format dspace
spelling my.iium.irep.554702022-11-07T03:52:35Z http://irep.iium.edu.my/55470/ Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction Helal Uddin, A.B.M. Alaama, Mohammed Kamarbashrudin, Siti Khadijah Rose Izat, I'zma QD Chemistry R Medicine (General) RS Pharmacy and materia medica The presence of pharmaceuticals in the environment had become a cause for snowballing concern in recent years. A wide range of pharmaceuticals had been discovered in fresh and marine waters and it had recently been shown that even in small quantities these compounds have the potential to cause detriment to aquatic life. Being ranked as number one in the Top 50 Drugs by Expenditures in the Malaysian Statistics on Medicine, amlodipine might also contribute to the emerging issue of pharmaceutical wastewater pollution. This research project is designed to develop a methodology in detecting amlodipine analysis in pharmaceutical wastewater. Cetrizine was used as internal standard and samples were analysed using Agilent 1200 Series RP- HPLC equipped with quaternary pump and auto injector. Samples were injected to C18 column and the mobile phase consisted of ammonium acetate buffer (pH=4 adjusted using glacial acetic acid) and acetonitrile in the ratio 60- 40. The flow rate was 1 ml/min and UV detector was used for the detection and the wavelength was 248nm. Solid phase extraction (SPE) is used in this study for the extraction of amlodipine and IS. The recovery of amlodipine was evaluated over three QC concentrations and the recovery was in the range of 65%-72%. The method was linear over the range of 30-5000 ng/ml of amlodipine in wastewater. In general, the method can be used for the analysis of amlodipine in wastewater. 2016 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/55470/1/PRC-2016.pdf Helal Uddin, A.B.M. and Alaama, Mohammed and Kamarbashrudin, Siti Khadijah Rose and Izat, I'zma (2016) Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction. In: 3rd Pharmaceutical Research Conference (3rd PRC 2016) for Pharmacy Students & Young Graduates, 28th-29th May 2016, Cyberjaya. (Unpublished)
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic QD Chemistry
R Medicine (General)
RS Pharmacy and materia medica
spellingShingle QD Chemistry
R Medicine (General)
RS Pharmacy and materia medica
Helal Uddin, A.B.M.
Alaama, Mohammed
Kamarbashrudin, Siti Khadijah Rose
Izat, I'zma
Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction
description The presence of pharmaceuticals in the environment had become a cause for snowballing concern in recent years. A wide range of pharmaceuticals had been discovered in fresh and marine waters and it had recently been shown that even in small quantities these compounds have the potential to cause detriment to aquatic life. Being ranked as number one in the Top 50 Drugs by Expenditures in the Malaysian Statistics on Medicine, amlodipine might also contribute to the emerging issue of pharmaceutical wastewater pollution. This research project is designed to develop a methodology in detecting amlodipine analysis in pharmaceutical wastewater. Cetrizine was used as internal standard and samples were analysed using Agilent 1200 Series RP- HPLC equipped with quaternary pump and auto injector. Samples were injected to C18 column and the mobile phase consisted of ammonium acetate buffer (pH=4 adjusted using glacial acetic acid) and acetonitrile in the ratio 60- 40. The flow rate was 1 ml/min and UV detector was used for the detection and the wavelength was 248nm. Solid phase extraction (SPE) is used in this study for the extraction of amlodipine and IS. The recovery of amlodipine was evaluated over three QC concentrations and the recovery was in the range of 65%-72%. The method was linear over the range of 30-5000 ng/ml of amlodipine in wastewater. In general, the method can be used for the analysis of amlodipine in wastewater.
format Conference or Workshop Item
author Helal Uddin, A.B.M.
Alaama, Mohammed
Kamarbashrudin, Siti Khadijah Rose
Izat, I'zma
author_facet Helal Uddin, A.B.M.
Alaama, Mohammed
Kamarbashrudin, Siti Khadijah Rose
Izat, I'zma
author_sort Helal Uddin, A.B.M.
title Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction
title_short Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction
title_full Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction
title_fullStr Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction
title_full_unstemmed Development and validation of new RP-HPLC method for the determination of amlodipine in pharmaceutical wastewater using SPE for extraction
title_sort development and validation of new rp-hplc method for the determination of amlodipine in pharmaceutical wastewater using spe for extraction
publishDate 2016
url http://irep.iium.edu.my/55470/1/PRC-2016.pdf
http://irep.iium.edu.my/55470/
_version_ 1751535888453599232
score 13.1944895